Instructions for use for the user
Filling the evaporator
CAUTION!
Scalding danger
If you pour water into the hot evaporator tank, hot steam is created.
● NEVER pour water into the hot evaporator tank.
● Check and fill the evaporator tank each time before starting
combi mode.
● If the overheating protection has switched off the heating of the evapo-
rator or if your sauna control unit reports a lack of water, allow the
evaporator to cool BEFORE you pour water into the evaporator tank.
CAUTION!
Scalding danger
If the evaporator tank is too full, boiling water sprays out of the evapora-
tor tank.
● Only fill the evaporator tank up to the maximum mark.
1. Remove the ceramic bowl 1 and the steam
funnel 2.
2. Place a receptacle (at least 5 litres) under the
ball valve on the bottom of the evaporator.
3. Turn the ball valve to the left until the remain-
ing water has flowed out.
4. When the evaporator tank 3 is empty, close
the ball valve.
5. Fill the evaporator tank 3 with fresh tap
water up to the maximum mark. You will need
about 5 litres of water for this. This amount of
water allows the evaporator to be operated
for approximately 1 hour.
6. Replace the ceramic bowl 1 and the steam funnel 2.