Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23

Service

During cleaning and service of the unit, the unit should be
disconnected from the power supply.
Th e fi ne fi lter should be changed at least once per year. If
the machine is used with a microfi lter/HEPA fi lter, this
should be changed every 300 running hours. Use breathing
protection when changing the fi lter. Care must be taken
during the fi lter change not to expose unprotected persons
to harmful dust. Used fi lters should be sealed in a plastic
sack and disposed properly.
Check regularly that the electrical cable is not damaged.
Th e DC 2900a/c/Auto should be performance tested at
least once per year because it may be used with hazardous
materials. Worn parts must be replaced.
Filter change:
Remove the motor head. Lift the fi lter straight up out of the
cyclone. When required, a plastic sack can be placed over
the cyclone for dust-free fi lter change. Th e fi lter is lifted
directly into the sack.
During the fi lter change, check the fi lter gasket. A dam-
aged gasket can allow the release of hazardous dust. Never
use old gaskets or after-market fi lters. Use only genuine
Dustcontrol spare parts to maintain the unit for use on
hazardous dusts.
Change of HEPA fi lter:
2014-6-26
For vacuum motor the typical average life of the ori-
ginal brushes is 600 - 700 hours. Th ey can then be
exchanged or complete motor/fan replaced. For 2nd
brush set life is ca. 400 hours and for 3rd brush set ca.
300 hours. After that the commutator is worn out and
the motor needs to be replaced.
Change of fi ne fi lter:
DC 2900a/c/Auto, 14
Part No 94164

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

94164

Table des Matières