USER SETTINGS
Only menu items followed by a greater-than symbol (>) may be adjusted. If no keys are selected for 5 minutes on screens: INLET OUT-
LET, GRAIN DPR (INLET-OUTLET for 230V models), the display will return to normal display mode. In all the other menu items, the
display with return to the normal display mode after 20 seconds. Items without the symbol (>) are for information only and cannot be
changed or reset.
Press
DISPLAY
MENU to proceed to
the next menu item. ↓
1. JOB HRS RESET >
PWR INTERRUPT X
2. INLET OUTLET
For information only.
100' 80% 115' 30%
3. GRAIN DPR
( XX.X g/kg for 230V models )
XX GPP
4. FILTER CLEANED
XXX HRS >
5. COIL CLEANED
XXX HRS >
6. HUMIDISTAT
MODE OFF >
7. HUMIDISTAT
SETPOINT XX% >
8. LANGUAGE
ENGLISH >
9. TEMP UNITS
'F >
10. COIL TEMP
For information only.
XX'
11. COMP CURRENT
For information only.
XX.X A
12. FIRMWARE
For information only.
3.0X FXXX-XXX
13. LIFE HOURS
XXXX HRS
(Returns to
top menu item.)
The following section available only on wireless-equipped units.
14. SENSOR ID
XXXXXXXX
(Returns to
top menu item.)
07-01913I F515-115V
Press
MENU SELECTION to change the setting.
1. JOB HR RESET 0
Press
PWR INTERRUPT 0
5. FILTER CLEANED
Press
0 HRS
5. COIL CLEANED
Press
0 HRS
6. HUMIDISTAT
Press
MODE ON >
Press
to cycle through 40%–90% at 5% increments (default is 50%).
8. IDIOMA
ESPANOL >
9. TEMP UNITS
Press
'C >
to reset to 0.
to clear filter hours.
to clear coil hours.
to turn ON or OFF.
8. SPRACHE
DEUTSCH >
FRANCAIS >
to change to °F or °C.
4
8. LANGUE
Press
to change lan-
guage options.