Remote Control damage
Damage to the Remote Control can be caused if you:
a)
use the Remote on a fence not powered by a SmartPower or Remote Capable Energizer or
b)
reverse the connection by placing the earth stake on the live fence wire and the brass terminal on the earth.
NOTE
If your Remote Control does not switch the Energizer ON or OFF, check:
1.
You are getting a good earth connection with your Remote Control. Use damp ground or connect the Remote
earth stake to a larger earth, like earth wire or iron fence stake.
2.
The Energizer earth is good.
3.
There is not a large short on the fence near where you are trying to operate the Remote Control. The Remote is
like a small Energizer. The pulses will power through small shorts but have difficulty with large shorts.
4.
The fence connections are good. Fault find connections by beginning at the Energizer and progressively working
towards where the Remote does not work. A Smartfix (G5090) or Digital Volt Meter (G5030) will assist. Use
Joint Clamps (G6030) to ensure good wire connections.
5.
The "Power/Standby" light is not flashing on the Energizer. If it is, this means there is high electrical interference
on the fence causing the Energizer to ignore the Remote Control signal. Refer to "Remote Control electrical
interference" section above.

TROUBLESHOOTING MR2500

Indicator Light Description
Constant green
Power/Standby
Constant yellow
Flashing red
Constant red
Flashing green
Fence
Flashing red
Fault
Energizer doesn't operate
Electric fence voltage is below
3000V or your stock are
escaping
8
Causes
Energizer is operating at
full power
Low Power
Electrical interference preventing
Energizer receiving clear Remote signal.
Remote has switched Energizer to
Standby mode.
Voltage is greater than 3.4kV
Voltage is less than 3.4kV. The
Energizer is reaching its limit for
effective animal control.

Pos si ble Cause(s)

Energizer Off
Break in supply circuit
Faulty Energizer
Inadequate earthing
Short on the fence line
Faulty Energizer
Gallagher 3E2410 MR2500 / MR5000 Energizer User Manual
Solution
None
None
Self corrects when interfeence reduces.
Reduce sensitivity via switches (see
illustration with "Remote Control
electrical interference" section).
Use Remote to switch Energizer ON
again or reset the power supply.
None
Fence maintenance is
required.
So lu tion
Switch ON
Test power point
Have Energizer repaired
Improve the earth system by adding more galvanised
earth stakes to the earth system until the earth voltage is
200V or below.
Check the electrical con nec tions are secure, eg. from the
fence to the red terminal, from the earth system to the
green terminal, at gates etc.
Check the voltage on the fence every 33m (100ft) using
the Digital Volt Meter (G5030). Note if the voltage is
dropping. The closer to a fault, the lower the voltage
reading will be. Become aware of things that cause faults
and always be on the lookout for: stray pieces of wire on
the fence, heavy vegetation growth, cracked or broken
in su la tors, broken wires.
Unplug the Energizer from the power supply and remove
the fence wire from the Red terminal. Plug Energizer
in again. Using a Digital Volt Meter (G5030) check the
voltage across the ter mi nals. If the voltage is less than
5000V, have Energizer repaired.