Declaration of conformity

The 4-channel auto-synchronous Active Infrared Barrier, type DIGITALK 2000, whether as a stand
alone or as a pillar-mounted integrated device, consists of:
Single unit transmitter and receiver, or
Pillar mounted transmitter and receiver
These products are in conformity with the standards on electromagnetic compatibility EMV
(89/336/EWG) in accordance with directives of the Council for Adaptation Adjustment. The comply with
the following electro-magnetic compatibility standards:

Technical Specification

Operating voltage
Current consumption
Recommended range
Theoretical range
Measuring period
Alarm output
Alarm response time
Armed/disarmed
input (receiver)
go test input
(transmitter)
first alarm memory
(receiver)
Disqualification
(receiver)
Technical alarm
Sync (transmitter)
Sabotage contact
Infrared beam
Alignment angle
Operating temperature
air humidity
Housing
Dimensions
Protection class
Weight
1.
EN50081-2
2.
EN50082-2
single unit
12-24 V AC or DC
70mA per pair (max. 100mA per pair)
high 100m / 200m
low
50m / 100m
≤ 10sek.
potential-free relay contact
max. load 200 V DC, 0.5 A, max. switching power 10 W
operating lag after alarm 5 sec.
50-300ms, adjustable at potentiometer
electrical input, towards COM (reference conductor I/O)
armed 0V-1.5 V/disarmed 3.5 V-Ub
electrical input, towards COM
go test off 0V-1.5 V/go test on 3.5 V-Ub
opto conductor output, open-collector towards COM
max. load 30 V DC, 50mA
opto conductor output, open-collector towards COM
max. load 30V DC, 50mA
opto conductor output, open-collector towards COM
max. load 30V DC, 50mA
operating lag 2 sec.
electrical in-/output (bi-directional) towards Sync-COM
potential-free switching contact
max. load 100 V DC, 0.2 A
wave length
940 nm
IR-impulse length
25 µs
pulse pause relation
1:200
keying ratio
2.5°
horizontal
± 90°
± 15°
vertical
-5°C - +70°C
-30° C - +70° C, with heating elements
≤ 98%
LxHxD (400x96x95) mm
IP54
pillar mounted unit
LxHxD (345x96x75) mm
IP44, w/pillar
-50-