ENGLISH
Description and operation
The product you have purchased is a flush-fitting
centrifugal extractor fan for wall or ceiling installation
(all models) or for fitting to a false ceiling or slab (I, I T
models only). It is used for the ventilation of rooms and
extraction into single ducts. All the models have an
IPX4-grade, spray protection, and are thus ideal for
installing in high-humidity environments.
LL Models:
The"LL" models have ball bearings motor that
guarantee at least 30,000 hours of silent, trouble-free
mechanical operation.
T (Timer) Models:
This models are equipped with a timer factory-set fora
minimum operating time of 3 minutes. The timer can
be adjuste to settings between approx. 3 and 20
minutes by means of the trimmer (see fig. 37).The
appliance switches on automatically a few seconds
after the light is switched on and continues to run for
the set time after the light is switched off.
T-HCS Model:
The appliance features a relative humidity sensor that
is factory set at 60%. When relative humidity exceeds
that level, the appliance automatically starts up. This
threshold setting can however be modified by the
installer to 4 levels: 60%, 70%, 80% and 90% (fig. 38).
The circuit is also equipped with a timer that can be
adjusted to settings between approx. 3 and 20
minutes by means of the trimmer (see fig. 38). The unit
switches on automatically a few seconds after the light
is switched on and continues to run for the preset
period of time after the light is switched off.
Safety
Warning:
!
this symbol indicates that care must
be taken to avoid injury to the user
• Do not use this appliance for functions other than
those described in this booklet
• After removing the appliance from its packaging,
ensure that it is complete and undamaged. If in
doubt contact a professionally qualified electrician or
Vortice. Do not leave packaging within the reach of
children or infirm persons
• Certain fundamental rules must be observed when
using any electrical appliance, including:
- never touch electrical appliances with wet or damp
hands;
- never touch appliances while barefoot;
- never allow children or infirm persons to operate
appliances unattended.
• Store the appliance out of the reach of children and
differently able persons after deciding to disconnect
it from the power supply and use it no more.
• Do not us the appliance where flammable vapours
are present (spirit, insecticides, petrol, etc.).
This appliance can be used by
•
children aged from 8 years and
above
and
reduced physical, sensory or
mental capabilities or lack of
experience and knowledge if
they
have
supervision
concerning use of the appliance
in a safe way and understand
the hazards involved. Children
shall
not
appliance. Cleaning and user
maintenance shall not be made
by children without supervision.
These appliances are designed
•
for
use
in
commercial properties.
The appliance must be installed
•
by a professionally qualified
electrician.
The electrical system to which
•
the product is connected must
be
in
compliance
applicable regulations.
persons
with
been
given
or
instruction
play
with
residential
with
the
and
7