Remote Controller - Ayce B0012 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SLEEP MODE
1. The
operation is effective when the unit is under
2. Press the
button in
mode, then the unit will work under sleep mode and the
indoor centrifugal fan will turn to low speed automatically. The set temperature will
increase 1 °C after one hour, and increase 2 °C after two hours. After six hours, the
unit will stop running.
NOTICE:
The main control board has memory function, when the unit is ready to run but in stop
status, the main control board can memorize the initialization of working mode. When you
turn on the unit, it will work as the same enactment of working-mode as last time, no
need to reset the working mode again. (This condition is not available when the unit is
under
mode).

REMOTE CONTROLLER

The remote controller transmits signals to the system.
1
POWER
DEHUM.
3
UP
MODE
5
DOWN
SPEED
7
TIMER
SLEEP
button-The appliance will be started when it is energized or will be stopped when it is in
1
operation, if you press this button.
2
buyyon-Can adjust the room humidity.
and
Setting Buttons Used to adjust the room temperature and the timer.
3 5
4
button-Used to select automatic、cool、fan mode.
6
button-Used to select fan speed in sequence.
stand for low 、middle、high fan speed.
button-Used to set automatic off and automatic on time.
7
8
button-Used to set or cancel
mode.
2
4
6
8
Mode operation.
PROTECTION
Operating conditionV
The protective device may trip and stop the appliance in the cases listed below:
Cooling
Indoor air temperature is over 43 °C.
Room temperature is below 15 °C.
Dehumidifying
Room temperature is below 15 °C.
If the air conditioner runs in cooling or dry mode with door or window opened for a long
time when relative humidity is above 80%, dew may drip down from the outlet.
Features of protector
The protective device will work in the following cases:
1. Restarting the unit at once after operation stops or changing mode during operation,
you need to wait 3 minutes.
2. If the plug is taken out, when you restart the appliance, it will return to the original
mode, TIMER ON and TIMER OFF must be set again.
DRAIN WATER
Special reminder: there is condensing water recycling hidden within this unit. The
condensing water is partly kept recycling between the condenser and the water plate.
When the water level rises to the upper level, the float switch and water full indicator (E4)
lights on to remind draining water. Please cut of the power supply, move the appliance to
a suitable place, remove the drain plug, drain water completely. After the drain, re-install
the plug, or the appliance may leak and make your room wet. If the unit is placed in a
position admitting drain water, you also can connect the drain hose to the drain port to
drain water.
MAINTENANCE
Appliance maintenance
1. Cut of the power supply.
2. Turn off the appliance first before disconnecting from power supply
3. Wipe with a soft and dry cloth.
4. Use lukewarm water (below 40℃) to clean if the appliance is very dirty.
5. Never use volatile substance such as gasoline or polishing powder to clean the appliance.
6. Never sprinkle water onto the main unit. Dangerous! Electric shock!
76 | 77
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Jumbo b0012Ygp35-1170zp

Table des Matières