Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
allows the machine to operate on a 16 A plug with proper protection for short periods e.g. to remove seized
bolts.
See connection instructions.
4. Remove the coolant reservoir cap, position the lance on its support with the cable on the ground.
5. Unscrew the inductor.
6. Fill the machine with cooling liquid up to maximum capacity.
7. Screw the inductor back on.
8. Switch the machine on using the main switch.
The device starts in fault mode.
9. Press the accessory switching button (10).
The cooling circuit is performing a purge cycle.
As soon as the cycle is over, the product is operational. Add some cooling liquid if necessary.
10. Close the coolant reservoir using the filler cap supplied in the plastic bag.
INSTRUCTIONS
1. Set the main switch (1) to ON. The machine initialises in 2 seconds.
2. Press the heat authorisation button (2) as described on page 5. The indicator on button (2) and the lance
support LED
(12) both switch on, indicating that the machine is ready to operate.
3. Position the inductor (13) flat on the workpiece (place the open part of the ferrite towards the workpiece).
4. Press the handle's button (11) to start the heating process ; if necessary, move the inductor on the
workpiece to heat a larger surface.
It is possible to change the rated power during the heating.
The display provides a continuous update of the cooling liquid temperature.
During the powering up phase, the pump and the cooling fan activate for a few seconds, to check that they
are wor- king properly.
After the heating stops, let the cooling circuit operate to cool down the inductor, before switching off the
machine.
To modify the cooling liquid temperature unit, press and hold both settings buttons (4) until the desired unit
is displayed (" -F-" = Farenheit / " -C- " = Celsius). Release the buttons, the change is saved and in effect.
The machine has been designed to minimise the risks due to electromagnetic
fields. Some residual risks persist and it is recommended to observe a security
distance between the inductor and the operator's head/torso.
Heat on standby
For security reasons, the product deactivates the heat authorisation after 5 minutes of inactivity. The heat
authorisation button indicator and the lance support LED both switch off.
To reactivate the machine, press the heat authorisation button (2) or press and hold the lance button (11) for
1 second. This feature is disabled after 20 minutes of inactivity.
It allows the user to stay in a working position without the need to reach for the machine.

WARNING LIGHTS

- The indicator 6 signals a machine/inductor fault.
POWERDUCTION 50 LG
23