No change in measurements if connected with drain
illustrated. (K-7193 or K-7193M)
Cut-out 73-1/2" (186.7 cm) x 39-1/2" (100.3 cm)
Pump/Control Access
40" (101.6 cm) W x 15" (38.1 cm) H
31-1/2" (80 cm)
2" (5.1 cm)
1" (2.5 cm)
1. Roughing In Information
NOTICE: The floor support under the whirlpool must provide for a minimum of 2000 lbs. (907.2 kg).
Two separate 240 V electrical services are required: one for the pump/control, and one for the
heater.
Consult local and national codes for minimum air gap requirements when installing a spout on the
faucet deck.
The overflowing bath must be filled through the bathing well.
Hot water supply should be 70% of the capacity or greater.
The fixture conforms to ANSI Standard Z124.1. All dimensions are nominal.
There is no change in measurements if connected with the drain illustrated (K-7193, K-7193M).
Cut-Out = 73-1/2" (186.7 cm) x 39-1/2" (100.3 cm)
An access panel is required. The recommended dimensions for this access panel are 40" (101.6 cm)
W x 15" (38.1 cm) H. Refer to the roughing-in diagram for suggested access panel location.
Make sure the flooring is in good condition and offers adequate support for your bath.
IMPORTANT! Verify that the subfloor is flat and level. This will help minimize the leveling adjustments
necessary for proper product performance.
1019731-2-C
75" (190.5 cm)
25"
(63.5 cm)
1" (2.5 cm)
2-7/8" (7.3 cm)
6
20-1/2"
(52.1 cm)
7-1/4"
16-13/16"
(18.4 cm)
(42.7 cm)
63" (160 cm)
1-1/2" NPS
3" (7.6 cm)
41"
(104.1 cm)
5-1/2"
(14 cm)
1-1/2" OD
Kohler Co.