5

Installation and connection

5.1

Installation planning

Note:
Use suitable transport and lifting aids to transport and install the unit.
The unit weighs more than 25 kg. (→ Technical data)
Plan the installation of the filter system. With careful planning, taking the ambient conditions into account, you
will obtain optimum operating results.
The following conditions must be met:
 As the filter modules are very heavy when filled, they must be placed on a suitable base (at least on slabs,
but preferably on a poured concrete base) to prevent them from subsiding.
 Plan sufficient space for carrying out cleaning and maintenance work.
 Drain the dirty water into the drain or far enough away from the pond so that it cannot flow back into the
pond.
– If the coarse soiling and dirty water both run into the same pipe, it is important to use at least DN 110
pipes.
 Use a suitable system for removing coarse soiling, e.g. ProfiClear Premium Drum Filter Module.
5.2

Information regarding pipes

 Use suitable pipes.
 Do not use any right-angled bends. Bends with a maximum angle of 45° are very efficient.
 Glue plastic pipes to ensure a permanent and reliable joint or use socket joints with clips to stop them from
coming apart.
 Standing water in pipes can freeze when there is a hard frost and cause pipes to burst. For this reason, lay
the pipes and hoses with a gradient (50 mm/m) to ensure that they can run empty.
 For gravity fed systems, it must be possible to shut off the supply from the pond and the return to the pond
for maintenance and repair work. For this reason, install suitable slide valves.
5.3

Installing the filter module and connecting it to additional filter modules

A maximum of three Moving Bed Modules can be installed one after the other.
How to proceed:
 G
1. Push the Moving Bed Module container towards the preceding module (Drum Filter Module or other Moving
Bed Module) until the outlet socket of the preceding module slides inside the rubber socket of the Moving
Bed Module up to the stop.
– The slide valves of the soiled water drains are all located on the same side.
2. Secure the connection with a hose clip.
3. First position the hose clip screw at the top, then tighten. This facilitates later installation steps.
Information about the pump fed system!
If no ProfiClear Premium Individual Module is connected to the last Moving Bed Module, OASE recommends
the following: To ensure an optimum water level in the container fit the ProfiClear Premium discharge set (Or-
der No.: 50949).