Potentiometer Adjustment - Erreka VIVO-M101 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
DIP
Modes and functions
DIP1
DIP2
Advance warning
DIP3
Opening mode
Automatic or step-by-step mode
DIP4
(for pedestrian and total operation)
Reverse impulse /
DIP5
close impulse
Automatic mode optional
DIP6
(only if DIP4 = ON)
Maintaining hydraulic pressure
DIP7
(for hydraulic operators only)
Soft stop (only for operators
DIP8
without mechanical absorber)
Anti-crushing function (obstacle
detection); the obstacles are only
DIP9
detected when the gate has come
to a complete halt.
Dead man function
DIP10
Only with DIP4=OFF and
DIP11=OFF
Interlock mode
DIP11
Only with DIP4=ON
DIP12 Safety device
P1 P2 P3
P4 P5 P6
ST1
FT1
ST2
FT2
8
Function and mode selection using SW2 (DIP1 = OFF)
Option
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF

Potentiometer adjustment

T.LG (garage light time): If the garage lighting circuit has been connected to
the control board, set the time which the lights shall remain on using T.LG.
T.E. (gate open standby time): if automatic functioning mode has been
programmed (DIP4=ON), set T.E. to adjust standby time with the gate open
(before automatic closing begins).
P.M (motor torque): use P.M. to adjust the maximum operator power value.
• Hydraulic operators: set P.M. at the maximum value.
• Electromechanical Actuators (anti-crushing function sensitivity): set P.M at
the minimum value possible, compatible with the proper operation of the
gate.
Adjust the torque to respect the maximum closing thrusts set out in
Standard EN12453:2000. Make the measurements as described in
Standard EN 12445:2000.
P15 P14 P16
P7 P8
P11 P12
P22 P
24Va
LOCK
FCA1
FCC1
STOP
P175M
Effect
the flashing light comes on and the operation begins after a 3 second
warning
the flashing light comes on and the operation begins immediately
step-by-step opening (the gate halts if a key device is enabled
during opening, and closes if enabled again)
collective opening (the control board does not obey the key
commands during opening)
automatic mode (the gate closes automatically after standby time
has passed, which is adjusted using T.E.). Standby time restarts if the
photocell is enabled.
step-by-step mode (the gate only closes when receiving the key
command)
recede impulse enabled. If soft stop is selected (DIP8=ON), a close
impulse is also carried out
close and recede impulse disabled
during standby, the gate obeys the key commands (can be closed
before standby time finishes)
the gate cannot be closed until standby time finishes; a key command
will cause standby time to restart
every two hours it carries out a close impulse in order to maintain
hydraulic pressure
maintain pressure disabled
the leaves reduce their speed before reaching the stopper
the leaves reach the stopper at high speed
Function activated: during quick travel, the gate detects obstacles
upon collision and recedes (when soft stop is activated, DIP8 = ON) or
remains shut down (when soft stop is disabled, DIP8 = OFF) in order
to prevent crushing
Function disabled
Dead man function enabled (opening is done by keeping ST1 pressed
down; closing is done by keeping ST2 pressed down)
Dead man function disabled
DIP10=ON: interlock mode with exterior and interior photocells
DIP10=OFF: interlock mode with exterior photocell
Interlock mode disabled
VULCAN S safety device connected in the FCA cable connectors
Device not connected