Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
PUL1: close mini-pushbutton
PUL2: open mini-pushbutton
• When pressing PUL1 (close), DL5 lights up
and the G2 and G3 cable connectors of the
operator are enabled.
• When pressing PUL2 (open), DL4 lights up
and the G1 and G3 cable connectors of the
operator are enabled.
DL1
Gate totally or partially open
DL1 - DL3 flashing: STOP contact
o p e n
( e m e r g e n c y
activated)
DL2
Receiving RSD plug-in receiver
radio signal (RUN/OK)
DL3
Radio
code
programming
DL4
Opening relay activated
DL5
Closing relay activated
DL6
Interior safety device contacts
(FT2) closed
6

General connections

DL12
DL6
DL10
DL11
DL9
DL7
FCA contacts closed
DL8
FCC contacts closed
s t o p
DL9
Exterior safety device contacts
(FT1) closed
DL10 Pedestrian key command (ST2)
DL11 Total key command (ST1)
or
operation
DL12 Plug-in receiver key command
(except RSD)
DL13 Garage light relay activated
DL14 Power supply
DL15 Electrolock relay activated
DL17 Triac M1 activated
SW2 Functions during programming (DIP1=ON)
DIP1=ON: programming enabled (DL3 lights up)
DIP1=ON and DIP2=ON: total open/close programming
DIP1=ON and DIP3=ON: pedestrian open/close programming
DIP1=ON and DIP4=ON: total opening radio code programming
DIP1=ON and DIP6=ON: pedestrian opening radio code programming
Turning direction: check operation using the
mini-pushbuttons PUL1 (close) and PUL2 (open).
If the turning direction of the operator is not
correct, interchange the cables connected in
cable connectors G1 and G2.
DL14
DL1
F3
DL13
DL15
DL7
DL8
DEST.
VIVO-M101: 230Vac
VIVO-M101M: 125Vac
VIVO-M101: 230Vac
VIVO-M101M: 125Vac
F2
DL17
O p e r a t o r
connections A:
G1 open
G2 close
F1
G3 common,
T: earth
(max. 40W)
LG
VIVO-M101: 230Vac, max 2,300W (resistive)
VIVO-M101M: 125Vac, max 1,250W (resistive)
Fuses:
F1 M1 Motor fuse
– M101: 2,5A (230Vac/50Hz)
– M101M: 6,3A (125Vac/60Hz)
F2 Electronic fuse
– M101: 0,5A (230Vac/50Hz)
– M101M: 1A (125Vac/60Hz)
F3 Output fuse 24Vac (315mA)
grey
connection
VIVO-M101:
230Vac/50Hz
VIVO-M101M:
125Vac/60Hz

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vivo-m101 m

Table des Matières