Before Use - Bosch GBH 2-22 S Instructions D'emploi

Masquer les pouces Voir aussi pour GBH 2-22 S:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14

Before Use

Auxiliary Handle (see Fig.
Operate the machine only with the auxiliary han-
dle 11.
By rotating the auxiliary handle 11 to a comfortable po-
sition, a fatigue-free and therefore safe working posi-
tion can be achieved.
Loosen the auxiliary handle 11 by turning counter
clockwise and swing it to the desired position. Then
retighten the auxiliary handle 11 by turning in the
clockwise direction.
Selection of Tools
For hammer drilling and chiselling (only with the acces-
sory MV 200), SDS-plus tools are necessary that are
inserted into the SDS drill chuck of the machine (see
SDS-Plus Tools).
For drilling in steel or wood, driving screws and cutting
threads, tools without SDS-plus (e.g., drills with cylin-
drical shafts) are used. For these tools, a special drill
chuck is required (see Working with Tools without
SDS-Plus).
Take care when changing tools that the dust pro-
tection cap 2 is not damaged.
SDS-Plus Tools
The SDS-plus tool is designed to be freely movable.
This causes eccentricity when the machine is off-load.
However, the drill automatically centres itself during
operation. This does not affect drilling precision.
Inserting a SDS-Plus Tool (see Fig.
Clean the tool before inserting and lightly grease the
insertion end.
Insert the tool with a twisting motion into the tool hold-
er 1 until it locks.
The tool locks itself. Check the locking by pulling on
the tool.
Removing SDS-Plus Tools (see Fig.
Pull the locking sleeve 3 to the rear (a) , hold it in this
position and remove the tool from the tool holder (b) .
1 619 929 563 • (02.12) T
3 OPERATING INSTRUCTIONS
)
A
)
B
)
C
English–3
Setting the Drilling Depth (see Fig.
With the depth stop 10 , the maximum drilling depth t
can be set.
Press the button 9 of the auxiliary handle and insert the
depth stop into the auxiliary handle 11 so that the
grooved side of the depth stop points downward.
Insert the SDS-plus tool to the stop into the tool
holder 1 . Otherwise, the freedom of motion of the SDS
tool can lead to an incorrect setting of the drilling depth.
Pull out the depth stop so far that the distance between
the drill tip and the tip of the depth stop corresponds to
the desired drilling depth t .
Dust Extraction with the
Vacuuming Attachment (Accessory)
For vacuuming dust, a dust extraction attachment (ac-
cessory) is required. While drilling, the dust extraction
attachment springs back so that the vacuuming head
is always held against the drilled surface.
Press the button 9 of the auxiliary handle and remove
the depth stop 10 . Press the button 9 again and insert
the dust extraction attachment from the front into the
auxiliary handle 11 (see Fig.
The maximum drilling depth t can also be set with the
dust extraction attachment mounted. For this pur-
pose, place the machine without switching on firmly
against the area to be drilled so that the drill rests on
the surface. Read the value from the scale of the dust
extraction attachment and add the desired drilling
depth t to this value.
Loosen the knurled screw on the depth stop of the
dust extraction attachment and slide the depth stop to
the calculated value. Then retighten the knurled screw
of the depth stop.
Connect a vacuum hose (19 mm Ø, accessory) to the
opening of the dust extraction attachment.
The vacuum cleaner (e.g., GAS ...) must be suitable
for the material to be worked.
When vacuuming dry dust that is especially detrimen-
tal to health or carcinogenic, use a special vacuum
cleaner.
)
D
).