Installation Instructions; General Product Information; Unit Location And Mounting; Required Tools For Installation - GE UUC112WC Instructions D'installation

Climatiseur bi-bloc à déchargeoir latéral
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS

General Product Information

Unpacking and Inspection:
This equipment is shipped completely assembled and
packaged. All goods are inspected at the factory and
released to the freight company in good condition. When
received at the site, a visual inspection should be made
immediately. Any evidence of rough handling or damage
should be photographed and noted on the delivery receipt
in the presence of the carrier. Claims for damage are to be
filed with the freight company.
Indoor Fan Time Delay:
For maximum cooling effect, the furnace or air handler
should be equipped with a time delay. Many popular
electronic thermostats have programmable fan delays,
newer furnaces and air handlers include them, and
universal delay kits are readily available on the market.
Model
12K
18K
Delay
115s
90s
Thermostat:
Accurate temperature control and unit operation depends
on proper thermostat selection and location. Refer to
the thermostat manufacturer's installation instructions
for specific recommendations. Avoid locating on outside
walls, in direct sunlight, in the air path of a supply register,
and in high traffic areas. Thermostats should be centrally
located, close to a return air grille.
System Protection:
A field-supplied liquid line filter-drier must be installed
to remove particulates or moisture that may collect in
the system during field work. Installations without a
filter‑drier may void the warranty.
Indoor Unit:
This product is compatible with most major brands of
domestic evaporator coils and air handlers equipped with
a thermostatic expansion valve. Consult AHRI's directory
of products for certified indoor unit matches.
Model
Power (outdoor)
PHASE
CIRCUIT BREAKER/FUSE (A)
MINIMUM CIRCUIT AMPACITY (A)
31-5000483 Rev. 3
24K
30K
36K
48K
90s
90s
100s
65s
12K
1PHASE
Volt
115 V
15
11

Unit Location and Mounting

Avoid areas where water, snow, ice, leaves, or other
seasonal debris may fall on or accumulate against the
unit.
Do not place the unit in a location where the minimum
clearances cannot be maintained.
For multiple unit installations, the clearance distances
shown below must be maintained.

Required Tools for Installation

• Drill
• 2 1/4" hole saw
• Vacuum pump and oil
• Leak solution or tester
• Tubing cutter
• Pipe reamer
• Razor knife
• Measuring tape
• Level
• Micron gauge
• Dry nitrogen and regulator
• Mini-Split AD-87 Adapter (1/4" to 5/16")
• Customary HVAC hand tools
• Core removal tool with micron gauge port
• Power and control wiring
• Drain hose (Included)
• Refrigerant scale
• Interior and exterior wall sealant
• 18 Gauge Thermostat Wire
• Brazing materials
18K
24K
1PHASE
1PHASE
208/230V
208/230V
15
15
10
12
30K
36K
1PHASE
1PHASE
208/230V
208/230V
20
25
15
16
48K
1PHASE
208/230V
40
25.5
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Uuc118wcUuc124wcUuc130wcUuc136wcUuc148wc

Table des Matières