Connecting The Inverter; General Instructions - Dometic SINEPOWER DSP 1312T Instructions De Montage Et De Service

Masquer les pouces Voir aussi pour SINEPOWER DSP 1312T:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 52

Connecting the inverter

9
Connecting the inverter
9.1

General instructions

!
WARNING!
• The inverter may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
• Never use the inverter on vehicles where the positive terminal of the
battery is connected to the chassis.
• If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
• When installed in vehicles or boats, the inverter must be connected to the chassis
or earth.
• When setting up a socket distribution circuit (mains setup), comply with the
applicable regulations.
• Only use copper cables.
• Keep the cables as short as possible (< 1 m).
• For grounding use a cable with a minimum cross section of 4 mm².
• Keep to the specified cable cross section and fit a cable fuse (fig. 6 1) as close
to the battery as possible on the positive cable (see the table).
Device
DSP1312T
DSP1324T
DSP1812T
DSP1824T
DSP2312T
DSP2324T
DSP3512T
DSP3524T
14
Required cable
cross section
35 mm²
25 mm²
50 mm²
25 mm²
70 mm²
35 mm²
2 x 50 mm²
50 mm²
SinePower
Cable fuse
200 A
150 A
250 A
150 A
300 A
200 A
2 x 250 A
250 A
EN

Publicité

Table des Matières
loading

Table des Matières