Operation Instructions Of The Control Panel; Control Panel; 1.2 . Operating Menu; Temperature Display - Helios KWL 500 W ET Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1.

Control panel

1.1. Keyboard
4
3
2
1
8
7
6
5

1.2 . Operating menu

The display of the operating menu (Sections 1.2.1.-1.2.5.) can be scrolled with the scrolling buttons.
(See Sections 1.1., legend numbers 5 and 6 in the figure).
1.2.1.
Main display and change of fan speed
3
21 C
10:20
1.2.2.
Moving to the settings menu
To settings menu
Press + and -
1.2.3.
Clock timer
Weekly program
ON
1.2.4.
Content display
RH1 35% RH2 40%
CO2
0821 PPM
1.2.5.

Temperature display

Out 20 In
20
Sup.
20 Exh. 20
1.2.6.
Settings supply air temperature
Temp. setting
20C
OPERATION INSTRCTIONS OF THE CONTROL PANEL
Start button
1
With this button, you switch the Unit KWL EC/ET 500
Pro on and off. When the indicator is lit, the unit is
on.
Carbon dioxide adjustment
2
With this button, you set carbon dioxide adjustment
on und off. When the indicator is lit, the adjustment
is on.
Humidity adjustment
3
With this button, you set humidity adjustment on and
off. When the indicator is lit, the adjustment is on.
Summer/winter function
4
With this button, you set summer or winter function
on and off. The winter function is active when the
indicator is lit and the mechanical heat recovery
bypass function is disabled.
Fan speed (you can change it with the
+ and - buttons).
Supply air temperature (21 °C)
Press + and - buttons simultaneously to enter the settings menu.
In this menu you can change the different settings of the KWL-unit.
The clock timer is activated by pressing the + key (symbol appears in the display) and
deactivated by pressing the – key. The clock timer controls the fan speed steps of the
ventilation unit.
(Programming of the weekly program see section 1.3.4.)
The content display schows humidity and CO
required (options).
The temperature display shows the temperature of outdoor air, indoor air, supply air
and exhaust air. The accuracy of the temperature sensors is
Without function!
Scrolling up
5
With this button, you can scroll the displays upward.
Scrolling down
6
With this button, you can scroll the displays
downward.
Increase button
7
With this button, you can increase values.
Decrease button
8
With this button, you can decrease values.
Fireplace or booster switch
Press + and - buttons simultaneously (>2 sec)
at the control panel to activate it.
Power failure
After a power failure, the unit starts at minimum fan
speed. The adjustment and setpoints chosen wil remain
in the memory of the unit in spite of the power failure.
Maintenance reminder alarm
Fireplace or booster switch on
clock timer (adjustable for each time of the
week) on
senors content. The corresponding sensors
2
13
±
2 °C.