Installation and Operating Instructions
CHAPTER 5
CLEANING AND
MAINTENANCE
WARNING
CHAPTER 6
FAULT DIAGNOSTICS
CHAPTER 7
WIRING DIAGRAMM-
OVERVIEW
for GB.. EC ...
7.0

Technical data of control input

Type
Poti feed-in
in V / mA
GBW EC 250
10V / 6 mA
GBW EC 315
10V / 6 mA
GBW EC 355
10V / 6 mA
GBW EC 400 A
10V / 6 mA
GBW EC 400 B
10V / 6 mA
GBW EC 450
10V / 6 mA
GBD EC 450
10V / 6 mA
GBD EC 500 A
10V / 6 mA
GBD EC 500 B
10V / 6 mA
GBD EC 560
10V / 6 mA
GBD EC 630
10V / 6 mA
GBD EC 710 A
10V / 6 mA
GBD EC 710 B
10V / 6 mA
Centrifugal fans – GigaBox GBW EC.. / GBD EC..
5.0

Cleaning and Maintenance

All work may only be carried out by a qualified person. All relevant safety regulation, national standards and
norms are to be adhered to!
Make sure before the cleaning that the unit is isolated from the mains and is secured against restarting
with an isolator switch!
- Impeller must stand still
– Clean unit only with a damp cloth.
– Excessive deposit of dirt, dust, grease and other materials on the impeller, motor and between casing and impeller is
to be avoided and has to be prevented by periodical cleaning.
– For maintenance purposes inspection doors and access openings must be provided in the duct system in a suitable
place.
– The motors have maintenance-free, long lasting, greased ball bearings.
6.0
Indications – Disturbance origins
Triggering of motor overheat protection (TK) can indicate:
– fan does not run on highest speed
– fan runs permanetly on highest speed
– build- up of dirt, hard running impeller and/or ball bearing failure
– too high air flow temperature
Abnormal noises can mean
– wrong direction of rotation
– worn out ball bearings
– bad vibration isolation to other buildings and ducting systems
Vibration can originate from
– unbalanced or dirty impellers
– insufficient vibration isolation from buildings and ducting systems
Extreme reductions in performance can occur
– with wrong direction of rotation
– if resistance to air stream through ducting and accessories (grilles, shutters, filters etc.) is higher than designed
Control input / set-value input
in V / A (Bürde)
0-10V / 0,1 mA (Ri=100 kOhm)
0-10V / 0,1 mA (Ri=100 kOhm)
0-10V / 0,1 mA (Ri=100 kOhm)
0-10V / 0,1 mA (Ri=100 kOhm)
0-10V / 0,063 mA (Ri=160 kOhm)
0-10V / 0,063 mA (Ri=160 kOhm)
0-10V / 0,08 mA (Ri=130 kOhm)
0-10V / 0,08 mA (Ri=130 kOhm)
0-10V / 0,08 mA (Ri=130 kOhm)
0-10V / 0,08 mA (Ri=130 kOhm)
0-10V / 0,08 mA (Ri=130 kOhm)
0-10V / 0,08 mA (Ri=130 kOhm)
0-10V / 0,08 mA (Ri=130 kOhm)
Number of potential fans
Number of potential fans with
with a potentiometer from
a potentiometer from a 10V
a 10V supply (without
supply (with PU/A LED)
PU/A LED)
47
47 LED over 24 V
47
47 LED over 24 V
47
47 LED over 24 V
47
47 LED over 24 V
75
75 LED over 24 V
75
75 LED over 24 V
59
59 LED over 24 V
59
59 LED over 24 V
59
59 LED over 24 V
59
59 LED over 24 V
59
59 LED over 24 V
59
59 LED over 24 V
59
59 LED over 24 V
7
UK
Number of potential
fans with EUR EC
100
100
100
100
100
100
100
100
100
100
100
100
100