- If the automatic shut-off function is enabled, the <
- Press any button to turn the device back on after it switches off automatically. You can also move the
rotary switch to the OFF position and then select the desired measuring function again.
- The automatic shut-off function can be disabled. Proceed as follows:
- Turn the current clamp off.
- Hold down the SELECT/V.F.C button (4) and turn the rotary switch (3) from the OFF
position to the desired measuring function. You will hear 5 beep tones and the <
is no longer visible on the LCD display.
- The automatic shut-off will be enabled again the next time you turn the device on and off.
b) Backlight
- The current clamp features a backlight so that the LCD display can be read easily.
- Turn the backlight on by pressing the HOLD/ button (10) for about 2 seconds. The backlight turns
off automatically after about 15 seconds.
- If you want to turn off the backlight off before the 15 seconds have passed, press the HOLD/ button
(10) for about 2 seconds.
c) HOLD function
- The HOLD function holds the measurement currently displayed on the LCD so that you can record
it or read it in your own time.
- To turn on the HOLD function, press the HOLD/ button (10); this action will be confirmed with a
beep and
(H) will be displayed on the LCD.
- To turn off the HOLD function, press the HOLD/ button again or change the measuring function.
46
You will hear 5 beeps every 15 minutes when the automatic shut-off is disabled.
> symbol (B) appears on the display.
> symbol