Measuring Resistance - CIMCO 11 1411 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- Turn on the device using the rotary switch and select the measurement range V
- Press and hold the SELECT/V.F.C button (4) for approx. 2 seconds to enable the low-pass filter. You
will hear 3 beep tones and < UFC > will be briefly displayed on the LCD display. < VFC > (D) will
then be displayed on the LCD.
- Proceed with the measurement according to steps 2 to 5 in "Measuring "AC" voltages (V
- To disable the low-pass filter, press and hold the SELECT/V.F.C button for approx. 2 seconds. You
will hear a beep tone and < End > will be briefly displayed on the LCD display.
Measuring "DC" voltages (V
- Turn on the device and select the measurement range V
(4) to switch to the DC measurement range. < DC > and < mV > appear on the display.
- Insert the red test lead into the V socket (8) and the black test lead into the COM socket (7).
- Connect both of the test prods to the measured object (battery, circuit etc.). The red test prod
corresponds to the positive terminal; the black test prod corresponds to the negative terminal.
- The current measured value is displayed together with the respective polarity on the display.
- After completing the measurement, remove the current clamp from the measured object and turn off
the device.
d) Measuring resistance
- Turn on the device and select the measurement range
- Insert the red test lead into the V socket (8) and the black test lead into the COM socket (7).
- Check the test leads by connecting the two test probes together. A resistance value of approx
0 - 1.5 Ohms should be shown (inherent resistance of the test leads).
42
)
A minus "-" symbol before the measured value indicates that the measured voltage
is negative (or the test leads have been reversed).
The "V DC/AC" voltage range has an input resistance of ≥10 MOhm.
Make sure that all objects to be measured including circuit compon-
ents, circuits and component parts are disconnected and discharged.
. Briefly press the SELECT/V.F.C button
Ω .
.
)".

Publicité

Table des Matières
loading

Table des Matières