Maintenance Operations; Nature And Frequency Of Checks; Maintenance Operations Which Do Not Require Qualified Technicians; Oil Level Check - Dometic T2500 H/HG-LP Instructions De Montage Et De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
3
The generator tends to stall.
Causes and Solutions:
3.1
No more fuel left in the tank: refill.
3.2
Low oil level.
Check and top up.
(See Maintenance section).
3.3
Air filter is dirty.
(Have checked by qualified personnel).
4
The generator does not produce current
Causes and Solutions:
4.1
Thermal switch off.
Set it to 'on' by pushing the switches (pos. 10 fig. 6
and 14) for 230V A.C., (pos. 11 fig. 6 and 14) for 12V
D.C.
4.2
Condenser (pos. 19 fig. 8) damaged.
(Have checked by qualified personnel).
4.3
Diode rectifier (pos. 21 fig. 8) damaged.
In this case, only the 12V D.C. and the green LED on
the control board are not working.
(Have checked by qualified personnel).
4.4
Rotor diodes damaged.
(Have checked by qualified personnel).
4.5
Frequency too low.
(Have checked by qualified personnel).
5
The unloaded current produced oscillates.
Causes and Solutions:
5.1
Too much oil in the engine: check.
5.2
Defective carburation.
Have the carburettor cleaned by qualified personnel.
5.0

MAINTENANCE OPERATIONS

IMPORTANT
Use only genuine spare parts. The generator may get
damaged if other than genuine parts having a different
quality standard are used.
To make sure that the generator keeps working to maximum
efficiency, it is essential that it is properly and regularly
maintained. Additionally, a proper maintenance grants the
generator a longer lifetime.
DANGER
Before carrying out any check or maintenance operation on
the genset, rotate safety switch (pos. 7 fig. 6 and 14) to "0"
position to prevent any accidental startings of the unit.
5.1

NATURE AND FREQUENCY OF CHECKS

ORDINARY MAINTENANCE INTERVAL
carry out at the intervals or after the running
hours given in the table, depending on which
occurs first.
Inspection
Engine oil
Change
Air filter
Cleaning
Spark plug
Inspection-Cleaning
Valve adjustment
Check - adjust
Fuel filter and tank
Cleaning
R.p.m.
or frequency
Adjust
Suspension points for
vibration dampers
Inspection
Fuel hoses
Check (replace,
if necessary)
REMARK (1):Clean more frequently when used in dusty areas
(2): Get this work done by a specialist only
5.2
MAINTENANCE OPERATIONS WHICH
DO NOT REQUIRE QUALIFIED
TECHNICIANS
To carry out these operations, the generator door first
needs to be opened. Therefore, the following measures
should be taken:
1) The generator must be stopped with all parts cold.
2) Let the unit cool.
3) Set the safety switch to the "0" position.
N.B.Remember to set it to the "I" position again after check!

OIL LEVEL CHECK

1) Remove the oil filling cap (pos. 9 fig. 8) and clean the
dipstick.
2) Reintroduce the dipstick by screwing it in fully.
3) Remove the dipstick and check that the oil level is
between min. and max. levels.
If not, top up with the recommended oil.
4) Refit the cap.
IMPORTANT
All checks should be carried out with the genset horizontal.
5.3
MAINTENANCE OPERATIONS WHICH
REQUIRE QUALIFIED TECHNICIANS
For some maintenance operations you need to slide the unit
out on its runners (pos. 28 fig. 7 and 15) after first loosening
the fixing screws.
6
Every
First
Every
Every
Every
month
3 months
6 months
year
use
or
or
or
or
20 hours
50 hours
100 hours
300 hours
▲(2)
▲(2)
(1) ▲(2)
▲(2)
▲(2)
▲(2)
▲(2)
▲(2)
▲ (2)
Every two years (2)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

T4000 h/hg-lpT5500 h/hg-lp

Table des Matières