15. Spares Parts and Accessories

Part no.
95083
Replacement power supply unit
95084
Replacement illuminator unit 850nm/30 degree angle
94032
Photocell extension kit – kit to allow photocell to be mounted remotely from PSU
95086
Replacement window
95087
Replacement photocell

16. Troubleshooting

WARNING: Disconnect from mains before removing the cover
WARNING. If this unit shows signs of damage or malfunction, disconnect from mains immediately
and contact Dennard LTD.
In dark conditions you will be able to see a faint red glow from the LEDs. In daylight you will not
see anything at all unless you look at the lamp with a camera.
Check mains supply is connected correctly and switched on. Supply should be 100-240V ~.
Check polarity of connections to lamp.
Check the photocell function (tape over photocell) and wait for a few seconds to see if the
product switches on.
Check the 2 A and 10 A fuses inside the PSU and replace if necessary.
Disconnect all control devices and switch all switches in the switch bank to the off position, to
check if the lamp illuminates.