see-thru fl ush
note:
Shaded components (fi nish framing) must be
non-combustible materials.
Finish framing must be built after the appliance has
been placed in its fi nal position and venting
connected.
Drywall
minimum framing
Ref
L38
K
39 15/16" (101.4cm)
E
16 3/16" (41.1cm)
F
53 13/16" (136.7cm)
J
Optional - Appliance does not need to be elevated above fl oor
73" (185.4cm)
L
fi nish framing - after appliance installation
Insulation
39 15/16" (101.4cm)
16 3/16" (41.1cm)
65 13/16" (167.2cm)
73" (185.4cm)
Ceiling
K
E
F
note:
L50
The L series requires a minimum enclo-
sure height of 73" measured from the
bottom of the appliance. For temperature
requirements, this area must be left un-
obstructed. Some venting confi gurations
that require more vertical rise will require
a larger enclosure to provide minimum
vertical clearance between vent pipes
and combustibles. It is also recommend-
ed that the enclosure be ventilated at the
top and bottom to circulate the hot air.
EN
L
J
45
W415-2033 / B / 02.04.20