5. Putting into Storage

Storage:
Disposal:
(in accordance with
RL2002/96/EC)

6. Maintenance

Clean priming area:
!
12
1489-20.960.06.indd 12
1489-20.960.06.indd 12
Before putting the pump into operation or switching it on,
please note: When first put into operation, the pump takes
about 60 seconds to vent after submersion in the water.
v Put the pump into operation only after this 60-second
submersion phase.
Once the pump has been put into operation, the end of the bleed ing
operation is indicated by a jet of water exiting the bleed openings.
The pump pumps and switches off automatically as soon as
no more water is drawn. Due to the check valve, the pressure is
maintained in the hose until water is drawn via the hose.
When water is drawn via the hose (the pressure in the hose falls
below 3.5 bar), the pump switches on automatically.
The pump switches off automatically when there is no fluid
pumped (the pump operates in cycles 30 secs. on – 5 secs. off
(4x). This cycle is repeated in 1 hr, 5 hrs, 24 hrs, 24 hrs ... ).
As soon as the inlet filter of the pump is again submersed at least
15cm in the water, the pump is ready to operate again.
The flow control switches off automatically as soon as no more
water is drawn. In the event of leakage on the pressure side
(e. g. leaking pressure hose or tap) switches the pump on and off at
short intervals. If the pump is switched on and off more frequently
than 7 x in 2 min. (with a leakage < 200 l/hr), the pump switches off
completely. When the leakage on the pressure side is eliminated,
the pump must be unplugged and plugged in again in order to be
operational again.
The built-in non-return valve prevents the water flowing back
through the pump.
The storage location must not be accessible to children.
v Store the pump away from frost before the first frost sets in.
The product must not be added to normal household waste.
It must be disposed of in line with local environmental regulations.
DANGER! Electric shock!
0
There is a risk of injury from electric
shocks.
V Disconnect the Deep Well Pump from the mains
power supply before carrying out maintenance.
1. Unscrew both screws
2. Clean priming area of the pump and inlet filter
q
3. Fix inlet filter
around the priming area again and screw tight
with the two screws
0
and remove the inlet filter
0
.
q
.
q
.
11.07.11 10:53
11.07.11 10:53