Econ SHL 100-Ex Notice D'utilisation page 23

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
Total discharge protection
In case of almost discharged battery (dis-play yellow/red) automatic change-over from main to
economy lamp.
Residual luminosity period: about  h
Note: When LED's are flashing the total discharge of battery is come up to
(Avoid that by all means!).
Network-automatic contactor function (emergency lamp function) –ON-
Should the line supply voltage is failing in the charging set during the charging the main lamp of
portable lamp will light up until the line supply voltage is coming back or the discharging limit of
battery is reached.
Only possible with charging set SHL 100-Ex!
A bridge b/c (22) is set onto the printed card, which ensures that emergency lamp function –
delivering condition.
Network-automatic contactor function –OFF-
If a emergency lamp function is not desi-red, e.g. in case of installation into motor vehicles with 2
V/24 V, the bridge (22) must be put onto the pins a/b. Including the following function:
a) no network-automatic contactor function
b) In case of abating of vehicle battery the charging operation will be interrupted by tension
regulation. So the battery of mo-tor vehicle will be preserved. Cut-off tensions at .7 V
or 23 V.
Operation „Plug into a different socket of bridge" see illustrations on page 26.
. Unscrew 3 Torx screws on the left and right at the housing and on the bottom (5).
2. Draw the back panel of casing (8) from the headlamp casing.
3. Bridge (22) on the electronic plate (2) is situated on b/c.
Draw the bridge off and pin it up on a/b.
4. Close and screw down the casing.
Attention: Take care of a good sealing (protection provided by enclosures)!
Is the sealing still okay?
22

Publicité

Table des Matières
loading

Table des Matières