4.
Unscrew and transfer the middle hinge
and the middle fixing plate
opposite position. (Fig. 5)
5.
Pop out the cover caps on the left side of
cabinet and use them to
on the right hand side.
6.
Screw the alternative left top hinge
included in the fittings,
cabinet. (Fig. 4)
7.
Relocate the door adapter
hinge.
8.
Set the upper glass door to the designated
position and install the two lock screws to
connect the door adapter
glass door and tighten them before the door is
leveled.
9.
Set the lower glass door to the designated
position and reassemble the bottom hinge.
10. Recheck and adjust the lower door alignment
by loosening the screws
moving the door adapter
the screws
,5 &
levelled. (Fig. 5)
11. Transfer the handles and plugs to the opposite
positions.

OPERATING YOUR APPLIANCE

This appliance is designed for operation at certain
ambient temperatures. The climate class is specified
on the rating plate.
The appliance may not work properly if it is left for a
long period at a temperature outside the specified
range. For example, placing your unit in extreme
cold
or
hot
conditions
temperatures to fluctuate. The range between 5ºC
and 22ºC (41ºF and 72ºF) may not be reached.
Climate class
Ambient room temperatures
SN
+10°C to +32°C
N
+16°C to +32°C
ST
+16°C to +38°C
T
+16°C to +43°C
NOTE:
Units with no heater will not raise their
internal temperature if the ambient temperature
where the unit is located is lower than the set
temperature.
,12
,11 to the
cover the screw holes
,9 ,
on the left hand side of
,14 on the middle
,14 with the upper
,5 &
,6 and
,4&
,7. Tighten
,6 after the door is
may
cause
interior
NOTE:
When you use the appliance for the
first time or restart the appliance after
having been shut off for a long time,
there could be a few degrees variance
between the temperature you select
and the one indicated on the LED
readout. This is normal and it is due
to the length of the activation time.
Once the unit is running for a few
hours everything will be back to
normal.
If the unit is unplugged, power lost, or
turned off, you must wait 3 to 5
minutes before restarting the unit. If
you attempt to restart before this time
delay, the unit will not start.
USE AND CONTROL (
DX-7.20SSK/DP, DAU-17.57DB, DAU-17.57DSS,
DAU-20.58B,DAU-20.58SS,DX-53.130DBK/DP,
DX-53.130SDSK/DP, DAB-28.65B, DAB-28.65SS,
DAB-36.80DB,
DX-57.146DSK, DAB-89.215DB, DAB-89.215DSS,
DX-89.215BDBK,DX-89.215BSDSK, DX-171.430PK)
USE AND CONTROL – SINGLE ZONE
The Controls of Your Unit
POWER
To turn the appliance on/off, press and hold the
key for 5 seconds until themperature display lights
up or goes out.
NOTE: Pressing the
audible alarm when the alarm is on.
LIGHT
Used to turn the inner light on/off.
UP
Used to increase (warm) the set temperature by
1°C/1ºF.
DOWN
Used to decrease (cool) the set temperature by
1°C/1ºF.
Display
Display
the
digital
indicators.
Indicator Light
The indicator light is located at the right lower corner
of the display. The indicator light will be on when the
multi-key function is selected. To perform the multi-
key function, press and hold the first key, then press
68
DX-7.20BK/DP,
DAB-36.80DSS,
DX-57.146DBK,
key once can switch off the
temperature
and
service

Publicité