Emergency Lowering - Upright X Série Guide De L'opérateur

Masquer les pouces Voir aussi pour X Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

E
L
MERGENCY
OWERING
If the platform should fail to lower, NEVER climb down the elevating
assembly.
The Emergency Lowering Valve for the X20N, X20W,
and X26N is located at the rear of the machine, above
the charger.
The Emergency Lowering Valve for the X32N is located
at the rear of the machine, to the left of the charger.
1. Open the Emergency Lowering Valve by pulling
and holding the knob.
2. To close, release the knob. The platform will not
elevate if the Emergency Lowering Valve is open.
X-Series Work Platform
W A R N I N G
!
!
Emergency Lowering Knob
Emergency Lowering Knob
Figure 5: Emergency Lowering Valve Handle
7