Charge the batteries at the end of each work shift or
sooner if batteries have been discharged.
1. Check battery fluid level. If electrolyte level is
lower than 10 mm (3/8 in.) above the plates,
add distilled water only.
2. Connect an extension cord to the battery
charger plug. Plug the extension cord
(1.5 mm² [12 gauge] minimum conductor
diameter; 15 m [50 ft.] maximum length) to
properly grounded outlet of correct voltage and
frequency.
3. The battery charger turns on automatically
after a short delay.
NOTE:
The battery charger circuit must be used with a GFI (Ground Fault Circuit Interrupt)
outlet.
DO NOT operate the machine while charger is plugged in.
Charge batteries only in a well-ventilated area.
Do not charge the batteries if the work platform is near a source of sparks or
flames.
Permanent damage to the batteries will result if the batteries are not
recharged immediately after discharging.
Never leave the battery charger operating for more than two days.
Never disconnect the cables from the batteries when the battery charger is
operating.
Keep the battery charger dry.