Operation
T
R A V E L
NOTE: The machine will travel at reduced speed when the platform is elevated.
1. Check that the route is clear of obstacles (persons, obstructions, holes, drop-offs, bumps, and debris), is
level, and is capable of supporting the wheel loads.
2. Check clearances above, below, and to the sides of platform.
3. Turn the Drive/Lift Switch to DRIVE.
4. Engage the Interlock Switch and move the Control Handle to FORWARD or REVERSE to travel in the
desired direction. The speed of the machine will vary depending on how far from center the Control Han-
dle is moved.
5. If the machine is not level the tilt alarm will sound and the machine will not lift or drive. If the tilt alarm
sounds the platform must be lowered and the machine moved to a firm, level surface before
attempting to re-elevate the platform.
L
O W E R I N G T H E
1. Turn the Drive/Lift Switch to LIFT.
2. Check around the base of the platform to ensure that no one is in contact with the machine. Engage the
Interlock Switch and pull back on the Control Handle to lower the platform.
3. The platform will stop when it reaches the PPE cut out height. To lower the platform fully, depress the
green PPE override button.
E
M E R G E N C Y
W A R N I N G
!
If the platform should fail to lower, NEVER climb
down the elevating assembly.
Stand clear of the elevating assembly while operating
the Emergency Lowering Valve Knob.
X20N, X20W
The Emergency Lowering Valve for the X20N,
X20W, and X26N is located at the rear of the
machine, above the charger.
1. Open the Emergency Lowering Valve by pulling
and holding the knob.
2. To close, release the knob. The platform will not
elevate if the Emergency Lowering Valve is open.

X32N

The Emergency Lowering Button for the X32N is
located at the Chassis Control Panel.
1. Open the Emergency Lowering Valve by pushing
and holding the button.
2. To close, release the button. The platform will not
elevate if the Emergency Lowering Valve is open.
Operation Manual
W
P
I T H T H E
L A T F O R M
P
L A T F O R M
L
O W E R I N G
X26N
AND
E
L E V A T E D
!
Emergency Lowering Knob
060572-025 X Series
Figure 5: Emergency Lowering Valve
Emergency Lowering KNOB