Pre-Operation Safety Inspection - Upright X Série Guide De L'opérateur

Masquer les pouces Voir aussi pour X Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

060572-025 X Series
P
-O
RE
PERATION
NOTE: Carefully read, understand and follow all safety rules, operating instructions, labels and National Safety
Instructions/Requirements. Perform the following steps each day before use.
1. Open modules and inspect for damage, fluid leaks or missing parts.
2. Check the level of the hydraulic fluid with
the platform fully lowered. The hydraulic
reservoir is located in the Control Mod-
ule Door. The fluid level must be
between the MIN and MAX lines. Add
hydraulic fluid if necessary.
3. Check that fluid level in the batteries is
correct.
4. Verify that batteries are charged.
5. Check that A.C. extension cord has
been disconnected from the plug in the
rear of the machine.
6. Check that all guardrails are in place
and all fasteners are properly tightened.
7. Inspect the machine thoroughly for
cracked welds and structural damage,
loose or missing hardware, hydraulic
leaks, damaged control cable, loose wire connections and wheel bolts.
Page 6
S
I
AFETY
NSPECTION

Pre-Operation Safety Inspection

Figure 3: Hydraulic Tank
Operation Manual

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

X20nX20wX26nX32n14000

Table des Matières