Terminals on the Outdoor Unit
Colour of wires (Connecting cables)
Terminals on the Tank Unit
(Power Supply Cord)
Terminals on the isolating device
from power supply (Disconnecting
means)
3
4
5
Terminal Board
*1
Holder (Clamper)
Bushing
Connecting Cable
Terminal screw
Tightening torque cN•m {kgf•cm}
M4
M5
*1 - Earth wire must be longer than other cables for safety reasons
CONNECTING REQUIREMENT
For Tank Unit with UX09HE8 / UX12HE8 / UX16HE8 / UD09HE8 / UD12HE8 / UD16HE8
The equipment's power supply 1 complies with IEC/EN 61000-3-2.
The equipment's power supply 1 complies with IEC/EN 61000-3-3 and can be connected to current supply network.
The equipment's power supply 2 complies with IEC/EN 61000-3-2.
The equipment's power supply 2 complies with IEC/EN 61000-3-3 and can be connected to current supply network.
CHARGING AND DISCHARGING THE WATER
5
Make sure all the piping installations are properly done before carry out below steps.
CHARGE THE WATER
For Domestic Hot Water Tank
1. Set the Domestic Hot Water Tank Discharge (Drain Tap)
"CLOSE"
Domestic Hot Water Tank Discharge (Drain Tap)
2. Set all Tap / Shower "OPEN".
3. Start fi lling water to the Domestic Hot Water Tank via Tube Connector i.
After 20~40min, water should fl ow out from Tap / Shower.
Else, please contact your local authorized dealer.
Check and make sure no water leaking at the tube connecting points.
4.
Set the Domestic Hot Water Tank Discharge (Drain Tap)
5.
set it "CLOSE".
Turn the Safety Relief Valve knob counterclockwise slightly and hold for 10 seconds to release air from this pipeline. Then
6.
recover the knob to original position.
Ensure Step 5 & 6 is carried out each time after charging water to Domestic Hot Water Tank.
7.
To prevent back pressure from happening to the Safety Relief Valve, do turn the Safety Relief Valve knob counterclockwise.
8.
ACXF60-04180_EN ES IT.indb 7
ACXF60-04180_EN ES IT.indb 7
Backup Heater
Main Power Supply
Power Supply
L
L
L
N
L
L
L
A1
A2
A3
B1
B2
B3
L
L
L
N
L
L
L
A1
A2
A3
B1
B2
B3
Power Supply 1
Power Supply 2
RCCB
*1
Power Supply Cable
157~196 {16~20}
196~245 {20~25}
to "CLOSE".
g
"OPEN"
g
1
2
3
4
5
N
1
2
3
4
5
Tank unit/Outdoor unit
N
connection
WIRE STRIPPING AND CONNECTING REQUIREMENT
Wire stripping
No loose strand
when insert
Conductor
fully insert
ACCEPT
to "OPEN" for 10 seconds to release air from this pipeline. Then
g
Indoor/outdoor
connecting
terminal board
5mm or more
(gap between wires)
Conductor
Conductor not
over insert
fully insert
PROHIBITED
PROHIBITED