UnpacKinG THe FiRepiT
When unpacking the firepit use gloves to protect from
sharp edges.
The contents include the firepit unit, instruction packet, hardware
package, and two burner prop supports which are located under
the firepit for shipping purposes only.
enclOSURe cOnTRUcTiOn
The firepit requires a custom built enclosure for support.
Combustible or non-combustible materials can be used. Minimum
internal enclosure dimensions are provided. See Figure 21.
Figures 22 and 23 give basic ideas for enclosure construction.
NOTICE: Measure firepit dimensions and verify framing or other
support methods before enclosure construction begins.
B
Ol48Tp
internal enclosure Dimensions (inches)
Height A
*7-1/2 Min.
Width B
51-3/4 Min. 52-1/2 Max. 63-3/4 Min. 64-1/2 Max.
Depth C 22-5/8 Min. 23-1/2 Max. 22-5/8 Min. 23-1/2 Max.
*NOTICE: Additional height will be required, if the drain pan
accessory is installed.
Figure 21 - internal enclosure Dimensions
Before completing the enclosure and installing firepit, provide a path
for water drainage out of the firepit.
Determine if the optional accessory drain pan will be used. If the
drain pan will be installed, follow the instructions provided with
the drain pan kit to install it at this point.
inSTallaTiOn
1.
Choose installation location.
Construct enclosure. See Figures 21, 22, and 23 for typical
2.
construction options.
3. Provide electrical service if LED's are included.
4. Provide for gas supply connections or Propane tank storage.
37795-3-0119
FiRepiT inSTallaTiOn (cOnT'D)
FIREPIT ENCLOSURE REQUIREMENTS
caUTiOn
C
A
Ol60Tp
*7-1/2 Min.
5. If installation includes Propane tank storage under the firepit,
use the optional BRB Vent Kit or refer to the Propane tank
storage requirements on pages 15 and 16. See Figure 19.
BBA LP
TANK DOOR KIT
(OPTION)
ENCLOSURE VENTING REQUIREMENTS
FOR LP TANK STORAGE UNDER FIREPIT
6. The photograph below shows a typical firepit installation for
reference only. See Figure 23.
BRB VENT KIT
REQUIRED OR
REFER TO LP
TANK STORAGE
REQUIREMENT
Figure 22
Figure 23