Installation is permissable within a partial enclosure that includes
an overhead cover and three side walls, as long as 30 percent or
more of the horizontal periphery (perimeter of walls and open side)
of the enclosure is permanently open. See Figures 9,10 and 11.
TOP VIEW
If installing in a screened in porch, the open space must be adjusted
(increased) from 30 percent (adjusted open space = 30% / % open
area of the screen mesh). "Example, if you used a screen with a
66% open area, the minimum open space of your building must
be 46% of the periphery. If you have a covered screened-in porch
that has two side walls that are 16', one wall that was against the
house that's 20' and one open side that's 20', you would have a
perimeter of 72'. You would need to have 33' of the perimeter open
(72' x 46% = 33')."
(contact your screen manufacturer or screen dealer to determine
your screens open area).

SIDE VIEW

Page 10
planninG inSTallaTiOn (cOnT'D)
STUDWALL
12"
MIN
12"
Figure 9
Figure 10
48" MIN
12"
FIREPIT
Figure 11
Vinyl Soffit, Vinyl Ceiling, Vinyl Overhang Disclaimer clearances
are to heat resistant material (i.e. wood, metal). This does
not include vinyl. empire comfort Systems inc. will not be
held responsible for heat damage caused from terminating
under vinyl overhangs, vinyl ceilings or vinyl ventilated/
unventilated soffits.
improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury
or loss of life. installation and service must be performed
by a qualified installer, service agency or the gas supplier.
GaS line cOnnecTiOn
The firepit is designed to accept a 3/8-in. gas line on OL48TP units,
and a 1/2-in. gas line on OL60TP units. Have the line installed by
a qualified service person in accordance with all building codes.
Consult local building codes to properly size the gas supply line
leading to the gas hook-up at the unit. The Commnowealth of
Massachusetts requires that a flexible fireplace connector cannot
exceed three feet in length. See Figure 12.
A flex-line connection to the valves is provided. The gas shut-off
valve (not supplied) must be located outside of the unit in an
accessible area.
Check gas type on the rating label located on the underside of the
control door. If the gas listed on the rating label does not match
your gas supply, DO NOT INSTALL. Contact your dealer for proper
model or conversion kit.
Always use an external regulator for all Propane fireplaces to reduce
the supply tank pressure to a maximum of 11 in. w.c.
connection directly to an unregulated l.p. tank can cause
an explosion.
Risk of fire, explosion or asphyxiation. Ensure no ignition,
flame or spark are near during installation. This includes
cigarettes or cell phones.
Leak test all connections with a soap and water solution. Bubble
formation will indicate a leak while under pressure. Use caution to
avoid burns.
caUTiOn
WaRninG
WaRninG
WaRninG
37795-3-0119