Solid fuels shall not be burned in this firepit.
The maximum gas inlet supply pressure is 11 in. for Propane
and 7 in. for Natural.
For firepits with a fixed fuel piping system and equipped with
a gas pressure regulator, the required manifold pressure in
inches water column: 11 in. for Propane and
4.5 in. Natural.
For firepits with a fixed fuel piping system and equipped with
a firepit gas pressure regulator, the firepit and its individual
shutoff valve must be disconnected from the gas supply pip-
ing system during any pressure testing of that system at test
pressures in excess of 1/2 psi (3.5 kPa).
The firepit must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
Check all local codes for requirements, especially for the size and
type of gas supply line required.
RecOMMenDeD MiniMUM GaS pipe DiaMeTeR
Schedule 40 pipe
pipe
inside Diameter
length
natural
0-10 feet
1/2 in.
0-3 meters
12.7mm
10-40 feet
1/2 in.
4-12 meters
12.7mm
40-100 feet
1/2 in.
13-30 meters
12.7mm
100-150 feet
3/4 in.
31-46 meters
19mm
NOTICE: Check to confirm whether your local codes allow plastic
or copper tubing for outdoor use.
NOTICE: Because some municipalities have additional local codes,
consult your local authority and installation code.
installing a Manual Gas Shut-Off Valve
Each firepit must have an accessible manual gas shut-off valve
located in the vicinity of the unit. Where none exists, or where its size
or location is not adequate, contact your local authorized installer
for installation or relocation.
Compounds used on threaded joints of gas piping shall be resistant
to the action of liquefied petroleum gases. The gas lines must be
checked for leaks by the installer. This should be done with a soap
solution watching for bubbles on all exposed connections, and if
unexposed, a pressure test should be made. To avoid damage to
the gas piping, remove all testing solution when testing is complete.
Never use an exposed flame to check for leaks. The firepit
must be disconnected from piping at inlet of control valve
and pipe capped or plugged for pressure test. never pressure
test with firepit connected; control valve will sustain damage!
Page 14
FiRepiT inSTallaTiOn (cOnT'D)
GAS SUPPLY
Tubing, Type l
Outside Diameter
propane
natural
propane
3/8 in.
1/2 in.
3/8 in.
9.5mm
12.7mm
9.5mm
1/2 in.
5/8 in.
1/2 in.
12.7mm
15.9mm
12.7mm
1/2 in.
3/4 in.
1/2 in.
12.7mm
19mm
12.7mm
1/2 in.
7/8 in.
3/4 in.
12.7mm
22.2mm
19mm
WaRninG
A gas valve and ground joint union should be installed in the gas
line upstream of the gas control to aid in servicing. It is required by
the National Fuel Gas Code that a drip line be installed near the
gas inlet. This should consist of a vertical length of pipe connected
into the gas line by a tee fiting with a cap on the bottom in which
condensation and foreign particles may collect.
The use of the following gas connectors is recommended:
— ANSI Z21.24 A ppliance Connectors of Corrugated Metal Tubing
and Fittings
— ANSI Z21.45 Assembled Flexible Appliance Connectors of
Other Than All-Metal Construction
The above connectors may be used if acceptable by the authority
having jurisdiction The Commonwealth of Massachusetts requires
that a flexible appliance connector cannot exceed three feet in length.
PROPANE GAS SUPPLY
LP GAS SUPPLY
LP GAS
SUPPLY
SHUT-OFF
FEMALE NPT to
VALVE
FEMALE NPT
NATURAL GAS SUPPLY
NAT GAS SUPPLY
NATURAL
NATURAL

GAS SUPPLY

GAS SUPPLY
MALE NPT to
SHUT-OFF
FEMALE NPT to
MALE FLARE
VALVE
FEMALE NPT
NOTICE: Gas shut-off valve shown. Other valves approved to
use with gas allowed.
Flex tubing to valve is pre-installed at the factory. Flare connector
is loosely installed for shipping purposes only. An accessible
manual gas shut-off valve must be installed external to the firepit.
LP GAS
MALE NPT to
SUPPLY
MALE FLARE
MALE NPT to
FLEX TUBING
VALVE
MALE FLARE
NIPPLE
MALE NPT to
MALE FLARE
FLEX TUBING
REGULATOR
Figure 18
37795-3-0119
VALVE