Signaling devices
Signaling devices
Courtesy light (contact rated for: 24 V - 25 W max).
Auxiliary connection of an outdoor light which can be positioned
where you like, to increase lighting in the driveway/parking area.
It stays on for a settable time.
See the [Courtesy Time] function in the [SET TIMES] menu.
Flashing light or cycle light
(contact rated for: 24 V - 25 W max).
Flashing light: it flashes during the gate's opening and
closing phases.
Cycle light: it stays on from the moment the leaf starts
opening until it again closes completely (including the
automatic-closing time)
See the [Light E] in the [FUNCTIONS].
Safety devices
Photocells
Configure contact CX, CY or CZ (NC), input for EN 12978
safety devices like photocells.
See [CX input], [CY input] or [CZ input].
- C1 reopening during closing. When the leaf is closing,
opening the contact causes the leaf to invert its direction of
movement until it is completely open;
- C2 closing during opening. When the leaf is opening ,
opening the contact causes the leaf to invert its direction of
movement until it is completely closed;
- C3 partial stop. Leaf stops, if it is moving, and sets up for
automatic closing (if the automatic closing function has been
activated;
- C4 obstruction wait. Leaf stops, if it is moving, and starts
back again once the obstruction is removed.
If unused, contacts CX, CY and CZ should be disabled
during programming.
Sensitive Safety Edges
Configure contact CX, CY or CZ (NC), input for EN 12978
safety devices such as sensitive safety-edges.
See [CX input], [CY input] or [CZ input].
- C7 reopening during closing. When the leaf is closing,
opening the contact causes the leaf to invert its direction
of movement until it is completely open;
- C8 reclosing during opening. When the leaf is opening,
opening the contact, causes it to invert its movement
until it is completely closed.
If unused, contacts CX, CY and CZ should be
disabled during programming.
C A
M E
DIR
RX
RX
DFW
Gate open warning light (Contact rated for:
24 V - 3 W max).
To warn that the gate is open.
It switches off when the gate is closed.
DELTA-S
DELTA
DFW with control
board of the DFI
connections
TX
TX