Signaling devices
Signaling devices
Courtesy light (contact rated for: 24 V - 25 W max).
Auxiliary connection of an outdoor light which can be positioned
where you like, to increase lighting in the driveway/parking area.
It stays on for a settable time.
See the [Courtesy Time] function in the [SET TIMES] menu.
Flashing light or cycle light
(contact rated for: 24 V - 25 W max).
Flashing light: it flashes during the gate's opening and
closing phases.
Cycle light: it stays on from the moment the leaf starts
opening until it again closes completely (including the
automatic-closing time)
See the [Light E] in the [FUNCTIONS].
Safety devices
Photocells
Configure contact CX, CY or CZ (NC), input for EN 12978
safety devices like photocells.
See [CX input], [CY input] or [CZ input].
- C1 reopening during closing. When the leaf is closing,
opening the contact causes the leaf to invert its direction of
movement until it is completely open;
- C2 closing during opening. When the leaf is opening ,
opening the contact causes the leaf to invert its direction of
movement until it is completely closed;
- C3 partial stop. Leaf stops, if it is moving, and sets up for
automatic closing (if the automatic closing function has been
activated;
- C4 obstruction wait. Leaf stops, if it is moving, and starts
back again once the obstruction is removed.
 If unused, contacts CX, CY and CZ should be disabled
during programming.
Sensitive Safety Edges
Configure contact CX, CY or CZ (NC), input for EN 12978
safety devices such as sensitive safety-edges.
See [CX input], [CY input] or [CZ input].
- C7 reopening during closing. When the leaf is closing,
opening the contact causes the leaf to invert its direction
of movement until it is completely open;
- C8 reclosing during opening. When the leaf is opening,
opening the contact, causes it to invert its movement
until it is completely closed.
 If unused, contacts CX, CY and CZ should be
disabled during programming.
C A
M E
DIR
RX
RX
DFW
Gate open warning light (Contact rated for:
24 V - 3 W max).
To warn that the gate is open.
It switches off when the gate is closed.
DELTA-S
DELTA
DFW with control
board of the DFI
connections
TX
TX