CAME ZLJ14 Manuel D'installation page 22

Masquer les pouces Voir aussi pour ZLJ14:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING! IMPROPER INSTALLATION MAY RESULT IN SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS
LEGEND
 This symbol shows which parts to read carefully.
⚠ This symbol shows which parts describe safety issues
☞ This symbol shows which parts to tell users about.
REFERENCE REGULATIONS
The product complies to the reference regulations in effect.
DESCRIPTION
Multi-function control pane for one-swing-leaf gates, with graphic programming-and-alert-display plus self-diagnosing of safety devices.
The functions on the input and output contacts, the time settings and user management, are set and viewed on the graphic display.
All connections are quick-fuse protected.
Intended use
Control panel
ZLJ14
Any installation and/or use other than that specified in this manual is forbidden.
Technical data
Type
Protection rating (IP)
Power supply (V - 50/60 Hz)
Maximum power (W)
Maximum power of the 24 V (W) accessories
Stand-by consumption (W)
Operating temperature (°C)
Items
Apparatus class
Fuses
- Line
- Card
- Accessories
- Motor
- Electrolock
Dimensions (mm)
IMPORTANT SAFETY INSTRUCTIONS WHEN INSTALLING
THIS MANUAL IS EXCLUSIVELY INTENDED FOR PROFESSIONAL, SKILLED STAFF
Gearmotor
AMICO - AXO - F4000 - FAST - FERNI - FROG - FROG J - MYTO
10 A - 250 V Ø 6.3x22 UFG632310
ZLJ14
54
230 AC
250
50
5
-20 ÷ +55
ABS
II
ZLJ14
1.6 A-F
630 mA-F
2 A-F
(Spare parts code 119RIR316)
3.15 A-F