True RMS Multimeter

7.Specifications

Function
Range
DC Voltage
50mV
500mV
5V
50V
500V
1000V
[1] Add 10 counts by temperature influence.
[2] Add 4 counts by temperature influence.
Function
Range
AC Voltage
50mV
500mV
5V
50V
500V
1000V
All AC voltage ranges are specified from 5% of range to
100% of range
Function
Range
(AC+DC)
50mV
500mV
5V
50V
500V
1000V
[1] Add 1% above 5k
32
Resolution
[1]
0.001mV
[2]
0.01mV
0.0001V
0.001V
0.01V
0.1V
Resolution
0.001mV
0.01mV
0.0001V
0.001V
0.01V
0.1V
Resolution
0.001mV
0.01mV
[1]
0.0001V
0.001V
0.01V
0.1V
Accuracy
(0.05% + 20)
(0.025% + 5digits)
(0.025% + 5digits)
(0.025% + 5digits)
(0.05% + 5digits)
(0.1% + 5)
Accuracy
50 to 10000Hz
50/60H (0.3% + 25)
z
<1KH (0.5% + 25)
z
<5KH (3% + 25)
z
Accuracy
0 to 1000Hz
<1KHZ(1% + 25)
<10KHZ(3.5% + 25)