CONSTRUCTION AND DIMENSIONAL DIAGRAM
MODEL RAM-60QH4
H a n d l e
1 5 7
( 2 6 )
A i r
s u c t i o n
Note:
1. Insulated pipes should be used for both small and large diameter pipes.
2. Piping length should be within 25m for one room and within 35m in total.
3. Height difference of piping between indoor unit and outdoor unit should be within 10m.
4. Overhead clearance of outdoor unit should be 200mm to allow servicing.
5. For electrical connection, please refer to the installation manual.
ATTENTION
During service, before opening the side cover, please switch off power supply.
9 1 4
7 9 2
A i r
o u t l e t
5 7
1 2
5 0 0
A b o v e
2 0 0
S e r v i c e s p a c e
– 24 –
2 7
9 6
L o n g h o l e s f o r a n c h o r b o l t
( 2 − φ 1 2 × 1 6 L o n g h o l e s φ 8 . 0 b o l t )
N o t c h f o r a n c h o r b o l t
( 2 − φ 8 . 0 b o l t )
3 7
1 4 7
A b o v e
1 0 0
Unit: mm
3 4 5
2 9 9
(1 9 )
6 8
6 0
A i r
s u c t i o n
H a n d l e
I n d o o r u n i t 1
S e r v i c e v a l v e ( φ 6 . 3 5 )
I n d o o r u n i t 1
室 内 機
S e r v i c e v a l v e ( φ 9 . 5 2 )
1
I n d o o r u n i t 2
室 内 機
2
S e r v i c e v a l v e (φ 6 . 3 5)
I n d o o r u n i t 2
S e r v i c e v a l v e (φ 9 . 5 2)
2 0 2