Connection Of The Alarm Inputs, Of The Twilight Switch And Of The Relays; Connection Of The Ethernet Cable - Videotec ULISSE NETCAM Manuel D'instructions

Unité pour cameras network
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.2.3.4 Connection of the alarm inputs, of
the twilight switch and of the relays
The installation is type TNV-1, do not
connect it to SELV circuits.
In order to reduce the risk of fire, only use
cable sizes greater than or equal to 26AWG
(0.13mm²).
All signal cables must be grouped together
by means of a strap.
Fig. 42
Relay contact connection.
Fig. 43
Alarm connection.
O1 C1 O2 C2
V
V
AGND
AL2
AL4
AL1
AL3
CONNECTION OF THE ALARM INPUTS, OF THE
TWILIGHT SWITCH AND OF THE RELAYS
Terminals
Description
O1-C1 and
Clean output contacts, can be activated by
O2-C2
alarm or by user control
AL1, AL2,
Self powered alarm inputs referring to AGND
AL3, AL4 and
AGND
Tab. 7
Connect the twilight switch to the AGND
and AL1 terminals. AL1 is the default alarm
contact for the light sensitive switch.

7.2.4 Connection of the ethernet cable

Connect the ethernet cable to the connector.
Fig. 44
Ethernet
27

Publicité

Table des Matières
loading

Table des Matières