Connection Of The 24Vac Power Supply Line; Connection Of The 120/230Vac Power Supply Line - Videotec ULISSE NETCAM Manuel D'instructions

Unité pour cameras network
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.2.3.2 Connection of the 24Vac power
supply line
Only for products marked UL intended for
the North American market, use a class 2 UL
listed transformer.
Power the device with an SELV type, 24Vac,
8A isolated source derived from a double
isolation UL Listed transformer specially
protected in output. Alternatively, use the
UPTIRPS120 power supply and control kit.
24Vac
GND
a
Fig. 40
Connect the power supply cables as described in the
table below.
CONNECTION OF THE POWER SUPPLY LINE
Colour
Power supply 24Vac
Defined by the installer
Defined by the installer
Yellow/Green
Tab. 5
26
CN1
24Vac
Terminals
24Vac
24Vac
GND
7.2.3.3 Connection of the 120/230Vac power
supply line
To connect the power supply line use the
appropriate junction-box (UPTjbUL). For
further information, refer to the product
use and installation manual.
N
GND
a
Fig. 41
Connect the power supply cables as described in the
table below.
CONNECTION OF THE POWER SUPPLY LINE
Colour
Power supply 230Vac
Blue
Brown
Yellow/Green
Power supply 120Vac
Blue
Brown
Yellow/Green
Tab. 6
CN1
L
Terminals
N (Neutral)
L (Phase)
GND
N (Neutral)
L (Phase)
GND