care to accompany it to the end (see figure 14).
6
Install the outer spiral. Slide it over the evaporator until its
hexagonal front notch engages with the hexagonal exposed
end of the magnetic outside rotor (see figure 15).
7
Push the bowl towards the rear wall of the unit until it fits
snugly around the gasket and its front fastening hooks are
properly engaged (see figure 16).
8
Use fresh product to chase any remaining sanitizer from the
bottom of the bowl(s). Drain this solution. Do not rinse out the
machine.
5. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the machine may
be performed, if needed, only as further precaution, in
addition to the Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare two gallons of a warm (45-60°C, 120-140 °F)
sanitizing solution (100 PPM chlorine residual) according to
your local Health Codes and manufacturer's specifications.
2
Pour the solution into the bowl(s).
3
Using a brush suitable for the purpose, wipe the solution on
all surfaces protruding above the solution-level and on the
underside of the top cover(s).
4
Install the top cover(s) and operate the unit. Allow the
solution to agitate for about two minutes. Drain the solution out
of the bowl(s).
5
Use fresh product to chase any remaining sanitizer from the
bottom of the bowl(s). Drain this solution. Do not rinse out the
machine.
figure 14
figure 15
figure 16

6 ROUTINE MAINTENANCE

ATTENTION
In case of damages, the power cord must be replaced by
qualified personnel only in order to prevent any shock
hazard.
1
Daily: inspect the machine for signs of product leaks past
seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication, worn
or damaged parts. Replace parts as needed.
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source by unplugging it.
ATTENTION
Condenser fins are very sharp. Use extreme caution
when cleaning.
2
In case of noise it needs to unplug the cooler and call for
service.
3
In case of failure unplug the machine, because unexpected
start again would be possible.
4
It needs to fix everything back in the initial position after any
repairmen, like screws and covers.
6. 1 MAINTENANCE (TO BE CARRIED
OUT BY QUALIFIED SERVICE
PERSONNEL ONLY)
1
Annually: remove the panels and clean the inside of the
machine including the base, side panels, condenser, etc.
2
Annually: Check if the auger bushings are worn out or
ovalized. If they are, replace them with new ones.
3
Never remove the insulating jacket from around the suction
tubing of the evaporator (the copper tubing located on the right
side of gear motor). In case the insulating jacket is missing
replace the entire parts with original spare parts from the
supplier.
4
In order to prevent any damages to the dispenser, all
plastics parts must be lubricated only with grease supplied by
the manufacturer or with another lubricating product suitable for
.
polycarbonate
16