Maintenance log
Malfunction
Possible cause
Stop valve on gas bottle closed
Supply source on the fridge
Refrigerator with no 12V supply
Stop valve at parking site closed
Not operating on gas
Supply tap closed
Gas bottle empty
Outdoor temperature too low
Faulty appliance
The living area circuit breaker has tripped
Supply source on the fridge
Vehicle connected to 230 V supply and control panel
Not operating on 230V
Operating voltage too low
Faulty battery
Faulty appliance
The living area circuit breaker has tripped
Not detecting when engine starts
Faulty charger fuse
Not operating on 12V
Faulty battery fuse
(while driving)
Faulty battery
12V base vehicle supply not working
Faulty appliance
Appliance needs to be turned on
Not cold
Faulty appliance
REFRIGERATOR
You can find the list of Le Voyageur dealers at www.levoyageur.fr
Solution
Open the stop valve
Check the power source on the fridge is set to GAS
Check on the ByPass unit that the fridge indicator is lit
Check water supply to the parking site
Open supply tap located in the kitchen (5.3 Supply systems)
Change gas bottle
Use propane (system operates exclusively on propane)
Contact an approved specialist
Reset the circuit breaker
Check the power source on the fridge is set to 230 V
Check on the ByPass unit that the fridge indicator is lit
Contact an approved specialist
Contact an approved specialist
Contact an approved specialist
Reset the circuit breaker
Indicator on the control panel
Replace the faulty fuse
Check the 50A fuse in the B1 unit
Contact an approved specialist
Contact an approved specialist
Contact an approved specialist
Wait approx. one hour for the fridge to start cooling
Contact an approved specialist