IMPORTANTES DIRECTIVES DE SÉCURITÉ
OPERATING PROCEDURES
USING THE TOOL
Complete all steps as indicated in PREPARING THE TOOL and LOADING FASTENERS
before using. This tool can be fired in two different ways:
1. Sequential Fire:
Turn the trigger mode selector (D, fig.2) so the tail of selector is up. (fig.7)
n
Put the contact tip (A, fig.2) of the tool on the working surface
n
Lightly push the tool toward the working surface until the safety bracket is depressed
n
Press the trigger (E, fig.2) to drive the fasteners. This "trigger fire" method provides
n
the most accurate fastener placement.
2. Bump Fire:
Turn the trigger mode selector (D, fig.2) so the tail of selector is down.(fig.7)
n
Hold the contact tip (A, fig.2) off the surface
n
Press the trigger
n
Keeping the trigger pressed, push the contact tip (A, fig.2) of the safety bracket
n
against the working surface. Once the bracket is pushed back enough, the nail will
fire.
CAUTION:
 Disconnect tool from air supply before performing maintenance, clearing a jammed
fastener, leaving working area, moving tool to another location or handing the tool to
another person.
 Clean and inspect tool daily. Carefully check for proper operation of trigger and
safety mechanism.
 Do not use the tool unless both the trigger and the safety mechanism are functional.
 Do not use the tool if its leaking air or needs any other repair.
FASTENER DEPTH
Driving depth can be adjusted by rotating the depth adjustment knob (B, fig.2).
Test fire a fastener into a scrap work piece and check depth.
n
If the nail is driven too deep, rotate the knob (B, fig.8) clockwise (when tool is
n
uPSIde-down) to move the safety bracket downward.
If a greater depth is desired, rotate the knob counter clockwise to adjust the safety
n
bracket upward.
Test fire another fastener in a scrap work piece and check the depth.
n
REPEAT AS NECESSARY UNTIL DESIRED DEPTH IS ACHIEVED. The amount of
n
air pressure required will vary depending on the size of the setting.
Determine the lowest setting that will consistently perform the job at hand. Excessive
n
air pressure may cause premature wear and/or damage to the tool.
CLEARING A JAMMED FASTENER
CAUTION: Disconnect tool from air supply.
1. Open latch
2. Rotate lower magazine
3. Remove the nails from the magzine.
4. Use a slender; soft steel rod to drive the drive blade to its uppermost position.
5. Use a pair of needle nose pliers to remove the jammed fastener.
6. Follow instructions in PREPARING THE TOOL BEFORE DRIVING to reload
fasteners.