Operating mode/operating time
The electric motor has been dimensioned for the S6 – 40% operating mode.
S6 = Continuous operation duty type
40% = refers to 10 min – 4 min. operation; 6 min. idle running.
If the motor is overloaded, it automatically switches off due to the winding thermostat inserted in the
motor winding. After a (variable) cooling period, the motor can be turned on again.
Defective electrical connection cables
Insulation damage can often occur on electrical connection cables.
Possible causes are:
Pressure points if connection cables have been run through window or door openings.
Kinks due to improper attachment or routing of the connection cable.
Cuts caused by running over the connection cable.
Insulation damage caused by pulling the connection cable out of the wall socket.
 Cracks caused by the aging of the insulation. Such defective electrical connection cables must not be
used and the insulation damage means they pose danger of death!
Regularly check the electrical connection cables for damage. Please make sure that the connection cables
are disconnected from the mains supply during the check. Electrical connection cables must meet the
applicable VDE and DIN regulations and the provisions of the local power supply company. Only use
connection cables labelled with H 07 RN. Labelling of the connection cable with the type specification is
mandatory.
Extension cables up to a length of 25m must have a cross section of 1.5mm², and cables with a length
exceeding 25m must have a minimum cross section of 2.5mm².
The mains connection is protected with a 16A delay-action
Three-phase current motor
The supply voltage must be 380-420V 50Hz.
The connection to the mains supply and the extension cables must be of a five-core type (3 P + N + SL).
The extension cables must have a minimum cross section of 1.5 mm².
The mains connection should be fused with a maximum of 16A.
The rotation direction needs to be rechecked whenever the mains connection and machine location is
changed. The polarity may also have to be switched.
Connections and repairs to the electrical equipment may only be performed by a qualified electrician.
If you have further questions, please specify the following:
Motor manufacturer and type
Motor current type
Data from the machine type plate
Data of the electric control
If you return the motor, always return the complete drive unit with the electrical control.
Page 42
fuse.