Declaration Of Compliance; Gas Technical Data Table; Electrical Technical Data Table; Installation - Lotus TPT-64G Instructions Pour L'installation Et L'emploi

Cuisieneres avec four usage professionale
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396 for the gas
part and with norm 73/23 for the electric part. The installation must be done observing the norms in force particularly
concerning room ventilation and discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
DIMENSIONS
MODEL
cm
TPT-64G
40x60x28h
100x60x28h
TP4T-610G
100x60x90h
TPF4-610G
TPF4-610GEM
100x60x90h
100x60x90h
TPFM4-610GEM
DIMENSIONS
MODEL
100x60x90h
TPF4-610G
TPF4-610GEM
100x60x90h
TPFM4-610GEM
100x60x90h
The operations for installing, conversions for use with other types of gas and starting up must be done only by
qualified personnel whose qualifications comply with the norms in force.
Gas installations, the electrical connections and the rooms in which the appliances are installed must comply with
the norms in force in the Country in which the installation is carried out; above all, the appliance must be installed
in a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas
emissions which are formed during combustion. The air necessary for combustion is 2m3 /h per kW of power
installed.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as
specified by regulations in effect.
The appliances installed in buildings open to the public must satisfy the following requirements.

Installation rules

The installation and maintenance of the appliance must be done according to the correct procedures and regulation texts
in use, particularly:
• safety standards for the prevention of fire and panic.
Connection and installation of appliance, ventilation and exhaust removal systems, shall be done according to the
Manufacturer's instructions and by qualified technicians and according to the regulations in effect. The electric wiring
shall conform to the regulations in effect. All fire prevention codes shall be observed.
a) General indications (Rules valid for GB only)
- For all appliances:
Gas safety Regulations, 1984; Health and safety at Work Act, 1974 Codes of Practice, BS 8173, 1982, The Building
Regulations 1985; The Building Standards Regulations, 1981, the IEE Regulations and the by-laws of the local Water
Undertaking.
The local gas Region or LPG supplier and the local authority and the relevant recommendation of the British Standards
(latest editions) concerned.
GB

DECLARATION OF COMPLIANCE

GAS TECHNICAL DATA TABLE

NOMINAL CAPACITY
Burner
Burner
3,5 kW
5,5 kW
/
/
2
2
2
2
2
2
2
2

ELECTRICAL TECHNICAL DATA TABLE

OVEN LAMP
cm
kW
0,015
0,015
0,015

INSTALLATION

CHECKING FOR ADEQUATE VENTILATION

IE
IT
CH
Oven
Grill
TP
kW
kW
kW
/
/
5,5
/
/
5,5
4
4
5,5
/
/
5,5
/
/
5,5
TOTAL
MAX.
POWER kW
ABSORB A
0,017
0,064
2,62
11,4
3,05
13,3
40
TOT. NOM.
Gas
CAPACITY
coupling
kW
ISO 7-1
5,5
R1/2GM
23,5
R1/2GM
27,5
R1/2GM
23,5
R1/2GM
23,5
R1/2GM
POWER
POWER
SUPPLY
SUPPLY
CABLE mm²
230Vac 50/60 Hz
3 x 1
230Vac 50/60 Hz
3 x 2,5
230Vac 50/60 Hz
3 x 2,5