<<2-zone temperature control>>
● A thermistor is built in the remote controller (Room RC) or the main controller (Main RC), or
TH1. The indoor unit refers to temperature monitored by a selected thermistor and controls
temperature for each zone.
● For 2-zone temperature control, one room sensor can be selected for Zone1 and Zone2 sep-
arately. The room sensor is used for monitoring room temperature.
● The selection of room sensor can be fixed or changed according to time, using a schedule
timer.
Note: Room sensor can be selected by main controller only.
Indoor unit
Living room Dining room
Receiver
* When
is shown on the remote controller, this indicates that the remote controller is used for
monitoring the room temperature. In this example, the living room temperature monitored by
remote controller 1 is regarded as the room temperature for Zone1. The bed room 2 temperature
monitored by remote controller 4 is regarded as the room temperature for Zone2.

5.2. Forced DHW

Hold down
button for 3 seconds or more
to allow the indoor unit to enter or exit the
forced DHW mode.
When the forced DHW mode ends,
goes out.
When
blinks after the button is held down for 3 seconds or more, this indicates
that the indoor unit that you use does not support this function.
8
Zone1
Address 1
Address 2
Zone2
Bed room 1 Bed room 2
Address 3
Address 4