10 seconds before turning off, a brief beep sounds and the indicator starts flashing. To
extend the operating time, press either the temperature control or press the red button. The
switch-off time is reset.
After switching off, the heater and pump are easily activated again by pressing the red
button. Shortly after heating up, the soldering tool is again ready for use.
3. Setting the temperature offset
The temperature at the soldering tool's exit point may be compromised by environmental
conditions. In this case, the temperature displayed might differ from the actual temperature.
The device is able to even up this difference in temperature by a corrective value (offset).
In order to determine the temperature difference, the temperature must be measured.
Determine the temperature by means of a thermometer with external sensor directly at the
soldering tool's exit port. Write down the measured value (T1).
Now read the actual temperature value on the soldering tool display (T2).
The difference of value T1 and T2 equals the offset value. Example: Measured temperature
300 °C (T1), actual temperature shown 320 °C (T2). T1 - T2 = 300 °C - 320 °C = -20 °C.
To turn this function on, press and hold the red button. The display shows "- - -".
Set the calculated offset value with the "SET TEMP" controller. Release the red button. The
value is stored and maintained also after turning the device off.
Notes on operation
1. Be careful when working with high temperatures!
Never use the device in close proximity to inflammable gases, paper and other
flammable materials! The hot air nozzle as well as the warmed up air are ex-
tremely hot and can lead to painful burns upon contact with them. Thus, never
touch the hot air nozzle with your hands! Make sure that the hot air can never
blow onto your skin! The white smoke at the beginning disappears shortly.
2. After its use, the device must cool down completely!
When you have switched off the device, it starts cooling down automatically by
blowing cool air through the hose. Never pull the mains plug out of the socket
during this phase but wait until this phase is completed!
3. Use the device carefully - do not expose it to mechanical stress!
The pipe in the hot air nozzle consists partly of fragile quartz glass.
4. We strongly recommend to unplug the device from the mains voltage
when it is not used for a longer period of time!
There is a small amount of current even in electrical devices that are connected
to the mains. For this reason, it is advisable to disconnect the device from the
mains!
Unsoldering
1. To melt the tin-solder, hold the hot air nozzle so that the nozzle adapter is positioned di-
rectly over the IC. (Direct contact between IC and adapter must absolutely be avoided!) The
tin-solder starts melting due to the emitting hot air.
2. Please remove the IC with pincers or tweezers as soon as the tin-solder is melted.
3. After you have removed the IC you can remove the remaining tin-solder with an unsolder-
ing pump.
Soldering
1. Apply e.g. the correct amount of SMD soldering paste and place the SMD piece on the
board!
2. Place the conductor board on a heating plate for pre-heating!
3. Heat the soldering position evenly with hot air!
4. Remove the remaining soldering material after the soldering process is finished!
Note:
We recommend that you check the amount of soldering material sufficiently. Sol-
dering with hot air requires special concentration. Otherwise unwanted jumpers or
over-sized soldering points could be the result!
Changing the fuse
Disconnect the device from the mains each time you replace the fuse.
The device is protected with a fuse. Unscrew the protective cap at the backside of the housing.
Remove the fuse. Replace it by a fuse of the same type (T3,15A 250 V, 5x20 mm). Screw the
protective cap tightly.
Maintenance, care & disposal
The safety instructions below must be noted before the device is cleaned or maintained:
Only a specialist who is familiar with the risks and relevant regulations may
carry out repairs or open the housing.
Before starting to clean or maintain, the device must be disconnected from
the mains!
This device is maintenance-free. Clean the exterior of the device only with a soft, dry cloth or
brush. Never use aggressive cleaning agents or chemical solutions since these might damage
the surface of the casing or impair the operation.
Error message
The device monitors parameters and heating elements automatically. However, if a malfunction
is detected, this will be shown as an error code on the display. Possible errors are:
Display "S-E":
Time-out at the temperature sensor, or the maximum temperature was exceeded. Reduce the
set temperature and let the device cool off. Turn the device off and on again. If you still receive
this error code, please contact Customer Service.
Display "H-E":
Short circuit at the temperature sensor, or time-out at the heating element. Please contact
Customer Service.
Display "C-E":
Control loop shows zero crossing error. Turn the unit off and on. If you still receive this error
code, please contact Customer Service.
Disposal
Regarding our environment and to enable full recycling of the used raw material, the
user is asked to bring the worn and defective devices to public collecting places for
electric scrap.
The symbol with the crossed out dust bin on wheels means that this product must be
brought to a recycling site for electric scrap for a best possible recycling of the raw
materials.

Technical data

Power supply ................................ 230 Volts / 50 Hz
Power consumption ...................... max. 550 Watts
Temperature range ....................... 100 °C to 480 °C
Air flow .......................................... max. 23 l / min.
Pump ............................................ Membrane pump
Noise level .................................... <52 dB(A)
Dimensions ................................... 245 x 187 x 135 mm
Weight .......................................... approx. 4 kg
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2019 by Conrad Electronic SE.
*2139974_V1_0719_02_dh_m_4L

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2139974

Table des Matières