2) GENERAL INFORMATION
Electromechanical operator designed to automate residential-type gates.
The gearmotor keeps the gate locked on closing and on opening, without
needing an electric lock for leaves up to 3 m long. For leaves ranging between
3m and 5m long, the electric lock becomes indispensable.
The operator is provided with an electronic torque limiter. It must be controlled
by an electronic control panel provided with torque setting.
The operator is provided with an obstacle detection system complying with
EN12453 and EN 12445 standards.

3) TECHNICAL SPECIFICATIONS

Power supply
Absorbed power
Absorbed current
Insulation class
Thermal protection
Pushing and towing force
Speed
Manual manoeuvre
Environmental conditions
Type of use
Maximum leaf length without
electric lock
Maximum leaf length with
electric lock
Maximum leaf weight
Degree of protection
Operator weight
Dimensions
Lubrification
(*other voltages to order).
MAXIMUM LENGTH/DOOR WEIGHT
Phobos AC A50
4) TUBE ARRANGEMENT Fig. A
Install the electrical system referring to the standards in force for electrical
systems CEI 64-8, IEC 364, harmonization document HD 384 and other
national standards.
Warning! For actuator wiring and accessory connection, refer to the relevant
instruction manuals. The control panels and accessories must be suitable for
use and conform to current standards.
Should the opening or closing direction be incorrect, it is possible to invert
the connections of operation 1 and operation 2 on the control board.
The first command after an interruption of the power supply should be an
opening manoeuvre.
5) INSTALLATION DIAGRAM Fig. B
P
rear bracket fastening to pillar
F
front fork fastening leaf
a-b distances for determining bracket "P" fastening point
C
value of fastening centre-to-centre distance
INSTALLATION MANUAL
single-phase 220-230V~ ±10% 50/60 Hz (*)
210 W
0,8 A
F
110 °C (self-resetting)
2000 N (~200 kg)
approx. 15 mm/s
Personalized release key
from -20 °C to + 55 °C
semi-intensive
1,8 m PHOBOS AC A25
3 m PHOBOS AC A50
2,5 m PHOBOS AC A25
5 m PHOBOS AC A50
4000 N (~400 kg) PHOBOS AC A25
5000 N (~500 kg) PHOBOS AC A50
IP X4
50N (~5kg) PHOBOS AC A25
77N (~7,7kg) PHOBOS AC A50
See Fig. L
permanent grease
WEIGHT [kg]
Phobos AC A25
D
gate length
X
distance from gate axis to corner of pillar
S
half door thickness
Z
value always greater than 45 mm (b - X)
kg
max. weight of leaf
α°
leaf opening angle
6) PILLAR FASTENINGS INSTALLATION DISTANCES Fig. B Rif. 2 - 3
6.1) How to read the installation distance tables
Select "a" and "b" according to the angle in degrees α° that the gate has to
open. The optimum "a" and "b" values for 92° opening at constant speed are
highlighted.
If there is too large a difference between "a" and "b", the leaf will not travel
smoothly and the pushing or pulling force will fluctuate during its stroke.
To respect the opening speed and ensure the controller operates correctly,
it is best to keep the difference between "a" and "b" as low as possible.
The table has been worked out for A50 mm (PHOBOS AC A50), 20 mm (PHO-
BOS AC A25) thick medium-size gate. Always check that there is no possible
collision between the gate and the operator.
7) FASTENING OF FITTINGS TO PILLAR Fig. C
8) POWER CABLE Fig. D
The board power supply cable must be of the H 05 RN-F type or equivalent.
The equivalent cable must guarantee:
- permanent outside use
- maximum temperature on the cable surface of +50° C
- minimum temperature of -25° C
The wiring of the terminal board must be carried out as shown in Fig. D Ref. 3:
MOT OP = operation 1
MOT CL
= operation 2
GND = earthing
MOT COM = common
Position the cable sheath so that O ring "K" is inserted in its housing in the
base and, leaving the sheath protrude by about J=5 mm (as shown in Fig. D
Ref. 3), close the hatch and fix it by means of the 3 screws.
If the motor vibrates but does not rotate, the problem may be:
- Incorrect wiring (see wiring diagram)
- If the leaf moves in the wrong direction, swap over the motor's start con-
nections in the control unit.
The first command following a mains power outage should be open STOP
LEAVES.
9) ATTACHING MOTOR TO FASTENING ON PILLAR Fig. E
10) MAXIMUM TILT Fig. F
11) CORRECT INSTALLATION Fig. G
Correct installation entails maintaining a rod stroke margin of approx. 5-10
mm to avoid possible trouble with operation. IMPORTANT: THE FRONT
BRACKET MUST BE FITTED WITH THE SLOTS FACING UP (FIG.G RIF.1).
12) FASTENING OF FITTINGS TO LEAF Fig. H
IMPORTANT: the front bracket must be fitted with the slots facing up (Fig. G
Ref. 1). Line up the front and rear brackets as shown in Fig. H Ref. 1.
13) OPERATOR ATTACHMENT ON DOOR Fig. I
14) ADJUSTMENT OF THE LIMITING DEVICES Fig. J
The correct adjustment of the limiting devices is obtained by setting the
working time on the control board correctly. Refer to the instructions of
the control board.
WARNING: If the time set on the control unit is insufficient, the leaves might
not complete their run.
Slightly increase the working time on the control unit.
15) DIMENSIONS Fig. L
16) TIPS FOR SPECIAL INSTALLATIONS Fig. M, N, O.
With the leaf fully open, create a recess to accommodate the operator.
Fig. M gives the minimum dimensions of the recess for the various PHOBOS
AC A25 - PHOBOS AC A50 models.
If distance "b" is greater than the values given in the installation tables:
- create a recess in the pillar Fig. N
- move the leaf so that it is flush with the pillar Fig. O.
17) LEAF STOPS AT GROUND LEVEL
For the actuator to work properly, it is advisable to use stops "Fig. P Rif. 1" to
stop the leaves both when they are open and closed, as illustrated in Fig. P.
The leaf stops must prevent the actuator rod from reaching the end of its travel.
18) MANUAL OPENING (See USER GUIDE -FIG.Y-).
19) ELECTRIC LOCK
WARNING: In the case of leaves longer than 3m, it is indispensable
to install a solenoid latch.
For electric lock connection, the optional board is required (refer to the
appropriate instruction).
PHOBOS AC A25 - PHOBOS AC A50 -
9