Velleman DVM101 Mode D'emploi page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
ranging mode ...................................................... auto + manual
ranges ................................................................................. 23
data hold ............................................................................ yes
backlight ............................................................................. yes
auto power-off ...................................................................... no
dimensions ..................................................... 177 x 92 x 40 mm
weight (with battery) ......................................................... 320 g
storage environment
temperature ................................................. -20 °C to 60 °C
humidity ............................................................ < 90 % RH
test lead probe (incl.) ...................... CAT IV 600 V, 15 A; L = 90 cm
9.1 DC VOLTAGE
range
2 V
20 V
200 V
600 V
Overload protection: 600 V DC or AC rms
Impedance: 10 MΩ
9.2 AC VOLTAGE
range
2 V
20 V
200 V
600 V
Average sensing, calibrated to rms of sine wave
Frequency range: 40-500 Hz
Overload protection: 600 V DC or AC rms
Impedance: 10 MΩ
V. 01 – 01/03/2017
Do not measure circuits that may contain voltages
> 600 VDC or > 600 VAC
resolution
1 mV
10 mV
100 mV
1 V
Do not measure circuits that may contain voltages
> 600 VDC or > 600 VAC
resolution
1 mV
10 mV
100 mV
1 V
DVM101
accuracy
± (0.5 % rdg + 2 digits)
± (0.8 % rdg + 2 digits)
accuracy
± (0.8 % rdg + 3 digits)
± (1.2 % rdg + 3 digits)
9
©Velleman nv

Publicité

Table des Matières
loading