Remote Control Programming - BFT ARGO Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
TABLE "B" - LOGIC MENU - (logic)
Logic
min.
max.
---
---
tca
---
---
ibl. open
---
---
3 step
---
---
pre-alar
---
---
hold-to-run
---
---
photoc. open
---
---
test phot
---
---
test bar
---
---
aster
---
---
fixed code
---
---
radio prog
---
---
sca-2ch
---
---
start - open
---
---
ped-close
---
---
change
ot.
INSTALLATION MANUAL
default
Definition
Automatic
OFF
Closing Time
OFF
Block Pulses
OFF
3 Step
OFF
Pre-alarm
OFF
Deadman
Photocells
OFF
during opening
OFF
Photocell test
Safety edge
OFF
testing
OFF
Master/Slave
OFF
Fixed code
Remote control
ON
programming
Gate open light or
OFF
2nd radio channel
Selection
OFF
START - OPEN
Selection
OFF
PEDESTRIAN -
CLOSE
OFF
Reversing motion
Description
ON
Switches automatic closing on
OFF
Switches automatic closing off
ON
The start pulse has no effect during opening.
OFF
The start pulse has effect during opening.
ON
Switches to 3-step logic. A start pulse has the following effects:
door closed: opens
during opening: stops and switches on TCA (if configured).
door open: closes
during closing: stops and opens again
OFF
Switches to 4-step logic. A start pulse has the following effects:
door closed: opens
during opening: stops and switches on TCA (if configured)
door open: closes
during closing: stops and does not switch on tca (stop)
ON
The flashing light comes on approx. 3 seconds before the motors start.
OFF
The flashing light comes on at the same time as the motors start
ON
Deadman mode during closing: opening operation performed in automatic mode;
closing operation continues as long as the control key is held down. (CLOSE).
OFF
Pulse operation (standard)
ON:
When beam is broken, operation of the photocell is switched off during opening. During
closing, movement is reversed immediately.
OFF: When beam is broken, photocells are active during both opening and closing. When
beam is broken during closing, movement is reversed only once the photocell is clea-
red.
ON
Switches photocell testing on
OFF
Switches photocell testing off
If disabled (OFF), it inhibits the photocell testing function, enabling connection of
devices not equipped with supplementary test contacts.
ON
Switches safety edge testing on
OFF
Switches safety edge testing off
If disabled (OFF), it inhibits the safety edge testing function, enabling connection of
devices not equipped with supplementary test contacts
ON
Control panel is set up as the Master unit in a centralized connection system.
OFF
Control panel is set up as a Slave unit in a centralized connection system.
ON
Receiver is configured for operation in fixed-code mode.
OFF
Receiver is configured for operation in rolling-code mode.
ON
Enables wireless memorizing of transmitters: (Fig. K)
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter
that has already been memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter
to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other
new transmitters.
This mode does not require access to the control panel.
OFF
Disables wireless memorizing of transmitters.
Transmitters are memorized only using the relevant Radio menu.
ON
The output between terminals 6-7 on the optional SCS-10 module is set as gate
open light: in this case, the 2nd radio channel controls pedestrian opening.
OFF
The output between terminals 6-7 on the optional SCS-10 module is set as 2nd radio
channel
ON
Input between terminals 3-4 works as OPEN.
OFF
Input between terminals 3-4 works as START
ON
Input between terminals 16-17 works as CLOSE.
OFF
Input between terminals 16-17 works as PEDESTRIAN
ON
Reverses motion of standard rotation (See Fig.I).
OFF
Standard rotation (See Fig.I).
17
ARGO-ARGO G -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Argo g

Table des Matières