Fault
The Ice Maker does not make
enough ice or the ice is
deformed.
The Ice Maker does not make
any ice.
The Light at the Ice and Water
Dispenser does not work.
Ice forms in the inflow hose
to the Ice Maker.
Water runs from the appliance. The Water Connection Hose is not
The water pressure is less than
usual.
Possible cause
The appliance or Ice Maker has only
just been switched On.
A lot of ice has been taken.
Low water pressure.
The Filter Cartridge is blocked or
needs to be replaced.
Temperature in the Freezer
Compartment is too warm.
The Ice Maker is switched Off.
The appliance is not supplied with
water.
Water Supply has kinks.
Low Water Pressure.
Temperature in the freezer space is
too warm.
Ice Cube Container is not properly
inserted.
Incorrect Shut Off Tap installed.
The Light is switched Off.
The Light is defective.
Low Water Pressure.
Shut Off Tap incorrectly opened.
properly sealed.
Incorrect Shut Off Tap installed.
Low Water Pressure.
Shut Off Tap incorrectly opened.
Incorrect Shut Off Tap installed.
Water Supply has kinks.
The Filter Cartridge is blocked or
needs to be replaced.
Remedial action
Approximately 24 hours is needed until ice
production starts.
Approximately 24 hours is needed until
the Ice Cube Container is filled again.
Connect the appliance to the stipulated
water pressure only (see chapter
"Connecting Appliance", section "Water
Connection").
Exchange the Filter Cartridge.
Set temperature slightly colder
in the Freezer Compartment.
Switch the Ice Maker On at the control
panel.
Contact the installer or the Water Supply
company.
Turn Off the Water Supply at the Shut Off
Tap. Smoothen out the kinks, exchange
where necessary.
Connect the appliance to the stipulated
water pressure only (see chapter
"Connecting Appliance", section "Water
Connection").
Check Freezer Compartment temperature
and, if required, set slightly colder.
Check the position, re-insert where
necessary.
Incorrect Shut Off Taps can cause low water
pressure and damage to the appliance.
Press the Button at the Ice and Water
Dispenser Control Panel.
See chapter "Light (LED)".
Connect the appliance to the stipulated
water pressure only (see chapter
"Connecting Appliance", section "Water
Connection").
Open Shut Off Tap fully.
Replace the hose with a manufacturer's
original part.
Incorrect taps can cause low water pressure
and damage to the appliance.
Connect the appliance to the stipulated
water pressure only (see chapter
"Connecting Appliance", section "Water
Connection").
Open Shut Off Tap fully and check for leaks.
Check the minimum through flow.
Incorrect taps can cause low water pressure
and damage to the appliance.
Turn Off the Water Supply at the Shut Off
Tap. Smoothen out the kinks, exchange
where necessary.
Exchanging the Filter Cartridge.
en-us